10.8 Demounting

1. Disconnect the panel PC from voltage.
2. Remove all connected cables.
3. Loosen the screws of the fastening elements.
4. Remove the fastening elements.
5. Press the detents of the installation aid from top. Ensure that the panel PC
is prevented from falling out of the mounting cut-out!
6. Remove the panel PC from the mounting frame.

10.9 Electric installation

10.9.1 Connecting the control cabinet PC to the operating display

Connection diagram
Control cabinet PC
Functional earth
Fig. 10-14: Wiring the control cabinet PC to the operating display
Connection
1. Connect the functional earth.
2. Connect the XCDI+tx interface at the control cabinet PC to the XCDi+rx
interface at the respective operating display using a CDI+ cable.
Mounting, demounting and electric installation
XCDI+tx
Operating display
XCDI+rx
R911384706_Edition 01 Bosch Rexroth AG