Transmitter Model Fct300 In Remote Mount Design; Hazardous Area Approval Cfmus - ABB CoriolisMaster FCB330 Commissioning Instruction

Coriolis mass flowmeter
Table of Contents

Advertisement

8.5

Transmitter model FCT300 in remote mount design

Ambient and process conditions:
T
-20 ... 60 °C (-4 ... 140 °F)
amb
Protection class
IP 65, IP 67, and NEMA 4X / Type 4X
8.5.1

Hazardous area approval cFMus

Specific coding according to FM applies depending on the design of the flowmeter sensor (integral or remote mount design).
IMPORTANT (NOTE)
ABB reserves the right to make changes to the Ex-marking. The exact marking can be found at the name plate of the meter.
Model FCT3xx-Y0... (Transmitter in General Purpose and Sensor in Zone 2, Div 2 or Zone 0, Div 1)
Approval
FM (marking US)
FM (marking Canada)
Model FCT3xx-F2... (Transmitter and Sensor in Zone 2, Div 2)
Approval
FM (marking US)
FM (marking Canada)
Marking
NI: CL I, II, III, Div 2 GPS ABCDEFG
DIP: CL II Div 1 GPS EFG
DIP: CL III, Div 1,2
NI: CL I, II, III, Div 2 GPS ABCDEFG
DIP: CL II Div 1 GPS EFG
DIP: CL III, Div 1,2
Marking
NI: CL I, II, III, Div 2 GPS ABCDEFG
DIP: CL II Div 1 GPS EFG
DIP: CL III, Div 1,2
CL I, ZN 2, AEx nA nR [ia] IIC T6
ZN 21 AEx tb [ia] IIIC T85°C
NI: CL I, II, III, Div 2 GPS ABCDEFG
DIP: CL II Div 1 GPS EFG
DIP: CL III, Div 1,2
Ex nA nR [ia] IIC T6
Comment
-
-
Comment
-
-
CoriolisMaster FCB330, FCB350, FCH330, FCH350 | CI/FCB300/FCH300-EN Rev. F 45