Programming - Operating Modes - Honeywell homexpert Rondostat COMFORT+ HR30 Manual

Electronic radiator controller
Table of Contents

Advertisement

Week program 1: at home all day
Factory preset time program is set for each day of the
week (Mo – Su):
20 °C
Lowering/
saving
16 °C
Switching
point 1
time
1
6:00 – 22:00
2
22:00 – 6:00
i
• Two further week programs are stored in the
radiator controller. Further information is available
in Section 9.
• You can also adapt one of the stored week
programs to your individual requirements, see
Section 8.
Modifying the temperature temporarily
If you want to change the temperature specified by the
time program temporarily:
fSet your desired temperature using the adjustment
dial.
The change remains in effect until the next switching
point.
i
The process of changing the temperatures
permanently is described in Section 7.
Saving energy in ECo mode
In ECO mode the room temperature in automatic mode
specified by the time program is decreased by 3 °C.
fTo activate ECO mode press the button AUTO/ECO/
MANU until
economy
The displayed temperature is reduced by 3 °C
ECO mode runs until you press the button AUTO/
ECO/MANU again and select a different operating
mode.
Heating
temperature
20 °C (Comfort temperature 1)
16 °C (Conserve temperature)
is displayed.
Manual mode
In manual mode the radiator controller operates at
the (manually) set temperature until you change the
temperature or change to a different operating mode.
fTo activate the manual mode press the button
AUTO/ECO/MANU until
The temperature can be adjusted manually using the
adjustment dial
Manual mode runs until you press the button AUTO/
Switching
ECO/MANU again and select a different operating
point 2
mode.
6. Programming – operating modes
overview of the operating modes
• "Party" operating mode: In this operating mode you
can specify a temperature for a number of hours.
After the set period has expired, the radiator controller
changes to automatic mode.
• "Day off" operating mode: If a public holiday lies
during the week, the automatic mode settings may
not meet your requirements on these days. In such
cases you can activate a "Day off" program for one
or more days. After the set period has expired, the
radiator controller changes to automatic mode.
• "Holiday" operating mode: In this operating mode
you can specify a temperature for a specific number
of days. After the set period has expired, the radiator
controller changes to automatic mode.
Selecting operating modes
Selecting the "Party" or "Holiday" operating
mode
1. Press the PROG button and turn the adjustment dial
to the left until
2. Confirm the selected operating mode with the
button.
Hours or Days flashes.
3. Use the adjustment dial to set the desired number of
hours or days and confirm with
The temperature display flashes.
4. Use the adjustment dial to set the desired temperature
.
and confirm with
The selected operating mode and the set temperature
are displayed.
- 5 -
manual
.
or
is displayed.
party
holiday
OK
.
OK
.
is displayed.
OK

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents