Adjustments; Blade Square To Table (90°) - Bosch 4405 Operating/Safety Instructions Manual

Bosch power miter saw operating instructions 4405
Hide thumbs Also See for 4405:
Table of Contents

Advertisement

Available languages

Available languages

Disconnect plug from power source
!
WARNING
before performing any assembly,
adjustment or repair to avoid possible injury.
NOTE: Your slide compound miter saw was com-
pletely adjusted at the factory. However, during ship-
ment, slight misalignment may have occurred. Check
the following settings and adjust if necessary prior to
using this compound miter saw.
Blade Square (90°)
To Table
90° Blade Alignment Check
1. Rotate table to 0° position and lock in place.
2. Make sure head assembly is pushed back fully
against stop and slide rail lock knob is tightened.
3. Lower head assembly. Lock in place.
4. Use a combination square to check blade square-
ness to table. Place the combination square on
the table and press it against the blade. If the
blade does not contact the full length of the
square, (Figure 6) follow the alignment procedure.
Combination
Square
Table
Figure 6. Blade Square to Table
90° Blade Alignment Adjustment
1. Loosen bevel lock handle.
2. Move the head off of the 0º stop.
3. Lower 0° stop screw and jam nut with 12mm
or adjustable wrench.
4. Move the saw back to 0º stop.
5. Push square against blade (fig. 6).
6. Adjust 0° bevel stop screw with 12mm or
adjustable wrench
contact with the full length of the square.
Tighten jam nut (Figure 7).

Adjustments

Blade
until the blade makes
13.
Figure 7. Bevel 0° Stop Screw and Jam Nut
7. Adjust bevel indicator. Loosen screw and
align indicator to the 0° mark. Tighten screw
(Figure 8).
Figure 8. Bevel Indicator
0º Stop
Screw
Jam
Nut
Adjust
to 0º
Bevel
Indicator
Screw

Advertisement

Table of Contents
loading

Table of Contents