1.4 Connecting Water Hoses
Set the water hoses along the torch cable and welding
cable, bind them together with plastic ties.
Keep binding up to end of the FA arm.
After fixing the water hose, connect them to a water cooling
unit and check that the hoses and cables have no extra
tension with the robot motion.
Note
• Connect the blue hose to supply water and the red hose
to drain water. Connecting the wrong hose could
cause torch burnout.
• Required cooling water flow rate:1.2L/min.
Recommended water cooling unit: Panasonic YX-
09KGC1
1.5 Inlet for Air Blow
This torch is provided with a hole for the air blow inlet at the
side of the air blow base. Refer to the following figure and
make a hole of 10 mm diameter in the air blow base cover,
and remove the sunk plug from the air blow base. Then
attach the attached elbow union instead.
Make a hole of φ
Air blow base cover
OM1105050JE03
14 mm
10 mm.
Bind
Note
Spatter tube for air blow unit is customer supplied.
Sunk plug
Elbow union
Installation
Bind
11