Technical data

Rated operating voltage U_b
Operating voltage range
Current consumption in idle at U_b=12V DC 6.0 mA
Mean current consumption (max. 0.6 sec.)
Current capacity of outputs (high active)
Bolt locking time
(Depending on operating voltage)
Signal duration of actuation signal
Installation position
Locking bolt:
Material
Diameter
Path
Bolt counter force
Shearing force (at side)
Cable connection:
Length
Diameter
Position
Magnetic contact:
VdS approval no.
Switching voltage
Switching current
Release range
Max. lateral offset
Type of protection DIN 40050 / EN 60529
Blocking element
Magnetic contact
Environmental class as per VdS
Operating temperature range
Storage temperature range
Dimensions W x H x D
Face plate, non-magnetic
1)
The stipulated value for the shearing force of 3 kN refers to a distance between the
face plate and the
threaded sleeve
of max. 4 mm (see Chapter 3).
12 V DC
9 V to 15 V DC
Approx. 0.2 A
50 mA max.
Approx. 0.8 to 1.2 sec.
³
30 ms
Random
Steel
8.0 mm
2 ±1.0
0
mm
2 kN
1)
3
kN
4 m
5.6
± 0.2 mm
at back, bottom or top
G104503 (
as per class B)
30 V DC
100 mA
10 mm to 20 mm
10 mm
IP 65 in installed condition
IP 67
III
-25 °C to +55 °C
-40 °C to +85 °C
18 x 140 x 32 mm (without face plate)
Standard dimension: 20 x 2 x 190 mm