∗ ∗ ∗ ∗ 29 IP/GSM Program Mode
Press ∗29 while in Data Field Programming mode. The following prompts appear.
E N A B L E I P / G S M ?
0 = N o , 1 = Y e s
1 = P R O G 2 = D I A G
0 = Q U I T
Normal and SHIFT key Functions While in ∗ ∗ ∗ ∗ 29 Menu Mode
Key
(A) = BS/ESC
(B) = ↓/↑
(C) = N/Y
(D) = SHIFT
1/A
2/B
3/C
4/D
5/E
6/F
7/S
8/T
9/X
[∗] / SPACE
0
[#] / ENTER
ÊK0735V4SUPP%Š
K0735V4SUPP 3/09 Rev. A
Enable IP/GSM?
0 = no, not using IP or GSM;
1 = yes using IP and/or GSM module
[∗] to continue
Programming /
Diagnostics Select
1= Prog (program the IP/GSM options)
2 = Diag (enter diagnostic mode)
0 = Quit; returns to data field mode
Normal Key Function
[BS]: Press to delete entry
Also can reset EEPROM defaults if "REVIEW?"
displayed
[↓]: Scroll down programming
[N]: Press for "NO" answer
Press before pressing a SHIFT key function. Will light READY LED. LED goes out once a key is
pressed. Press again for each SHIFT function desired.
[1]: For entering the number 1
[2]: For entering the number 2
[3]: For entering the number 3
[4]: For entering the number 4
[5]: For entering the number 5
[6]: For entering the number 6
[7]: For entering the number 7
[8]: For entering the number 8
[9]: For entering the number 9
[∗]: Used to select programming options
[0]: For entering the number 0
[#] / ENTER: Press to accept entries
If using a communication device, enter 1 at this prompt and enter 1-Prog
at the next prompt to program the device. Use the communication
device's Installation Guide for details of the device's programming
prompts and instructions for registration.
[Default = 0 (no IP and/or GSM)]
Select whether you want to program the communication device or enter
the device's diagnostic mode.
Diagnostic Mode Note: Diagnostic mode option available only for
communicators with firmware version 2.4.16 or higher.
SHIFT Key Function
[ESC]: Press to quit Program Mode
[↑]: Scroll up programming
[Y]: Press SHIFT-Y for "YES" answer
[A]: Used for entering C.S. ID number
[B]: Used for entering C.S. ID number
[C]: Used for entering C.S. ID number
[D]: Used for entering C.S. ID number
[E]: Used for entering C.S. ID number
[F]: Used for entering C.S. ID number
[S]: Press to display diagnostic status
[T]: Press to send TEST messages
[X]: Press to reset the IP/GSM
[SPACE]: Not used
No SHIFT function