Relay
Contact
Terminals
Power Switch
Cable Gland
The terminals used are suitable for conductors of 24 to 14 AWG (0.5 to
1.8mm Dia.). We recommend using the 16 AWG (1.5 mm Dia.) conductors.
If Power over Ethernet (PoE) is used to power the device, then 24 VDC
power must not also be connected to the device, (or conversely if 24 VDC
is used to power the Midas M, then electrical power via the Ethernet port
must not be applied). Failure to observe this requirement may cause dam-
age to the gas detection system and will not be covered by the standard
warranty.
When connecting the wires, ensure that the power switch is in the off
position.
4-20mA Analog Output
Switches (4 Channels)
4-20mA Analog Output
Switches (4 Channels)
24Vdc Power Terminals
Optimal
Relays
Connector
RJ45 Connector