Bosch Conettix B465 Installation And Operation Manual page 110

Universal dual path communicator
Hide thumbs Also See for Conettix B465:
Table of Contents

Advertisement

110 en | Specifications and certifications
3-302-99-iii
LOW SYSTEM BATT (restoral)
1-303-99-000
RAM CHECKSUM BAD
3-303-99-000
RAM CHECKSUM BAD (restoral)
1-304-99-000
ROM CHECKSUM BAD
1-305-99-000
SYSTEM RESET
1-306-99-000
PANEL PROG CHANGE
1-311-99-000
BATTERY MISSING
3-311-99-000
BATTERY MISSING (restoral)
2017.11 | 05 | F.01U.311.207
Contact ID report
(i = input number, 001-004)
(t = trouble type)
Installation and Operation Manual
Conettix Universal Dual Path Communicator
B465 Event
When a B465 input that is configured for
Panel Low / missing Battery returns to
normal after being shorted, the B465 makes
a Panel Low / missing Battery Restoral event
and sends a, LOW SYSTEM BATT restoral
report.
When the battery voltage for the B465
returns to normal after being low, the B465
makes a battery restoral event and sends a
LOW SYSTEM BATT Restoral report (iii =
000).
When the checksum for the B465
configuration parameters is incorrect, the
B465 makes a Configuration Checksum
Failure event and sends a RAM CHECKSUM
BAD report.
When the checksum for the B465
configuration parameters is corrected, the
B465 makes a Configuration Checksum
Restoral event and sends a RAM CHECKSUM
BAD restoral report.
When the checksum for the B465 firmware is
incorrect, the B465 makes a Firmware
Checksum Failure event and sends a ROM
CHECKSUM BAD report.
When the B465 resets (restarts), it makes a
reset event and sends a SYSTEM RESET
report.
When the B465 configuration parameters are
changed by RPS or by the USB interface, the
B465 sends a PANEL PROGRAMMING
CHANGED report.
When the battery for the B465 is missing (or
dead), the B465 makes a battery missing
event and sends an BATTERY MISSING
report (iii = 000).
When the battery voltage for the B465
returns to normal after a battery missing
event, the B465 makes a battery restoral
event and sends a BATTERY MISSING
Restoral report (iii = 000).
B465 Event #
6
31
32
30
27
35
19
20
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading