Download Print this page
Camplux CA528 Use & Care Manual

Camplux CA528 Use & Care Manual

20l residential indoor tankless

Advertisement

CAMPLUX 20L
Residential Indoor Tankless
Gas Water Heater
USE & CARE MANUAL
(844) 538-7475
3330-A Marathon Ct Charleston, SC 29418
support@camplux.com
Visit Us: Camplux.com

Advertisement

loading

Summary of Contents for Camplux CA528

  • Page 1 CAMPLUX 20L Residential Indoor Tankless Gas Water Heater USE & CARE MANUAL (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 2 - If you cannot reach your gas supplier, call the fire department. • Installation and service must be performed by a qualified installer, service agency or the gas supplier. 150 PSI 150 PSI (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 3 We highly suggest you take the time to read through all of the safety and installation procedures in this manual, before attempting to install your new residential water heater. Always remember we're here for you via our online helpdesk located at www.camplux.com, live chat and toll free at (844)538-7475! READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your water heater properly.
  • Page 4 FOR YOUR RECORDS Please Note: In order to file a product warranty claim, the original proof of purchase is required. Manufacturer: Camplux, enjoy outdoor life. Add: 3330-A Marathon Ct North Charleston, SC 29418. (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com...
  • Page 5: Table Of Contents

    Be sure to inspect the flue terminal for proper installation at initial start-up. and at least annually thereafter. Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 6 Is at least 18” above the floor. This will reduce, but not eliminate, the risk of vapors being ignited by the main burner flame. Read and follow water heater warnings and Instructions. If owners manual is missing, contact the retailer or manufacturer. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 7 Contact a licensed plumber or the local plumbing authority for further informa- tion. NOTICE: The factory recommended operating temperatures are between 90°F and 140°F. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 8 For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 9 Park, Quincy, MA 02269 as NFPA 54. In Canada, the latest edition of the CSA B149.1 Natural Gas and Propane Installation, and the Canadian Electrical Code, CSA C22.1Part1, in the absence of local codes. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 10 • If the clearances stated on the Instruction/Warning Label, located on the front panel of the heater differ, install the water heater according to the clearances stated on the manual. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 11 The water heater warranty is voided when failure of the water heater is due to operation in a corrosive atmo- sphere. NOTICE: The water heater should not be installed near an any air supply containing halogenated hydrocarbons. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 12: Installing The Water Heater

    Expansion Tank Shut Off (Supplied) (If Needed) Gas Supply Line To Hot Water Remote Control (Sold Separately) Faucet(s) Pressure Relief Valve(Supplied) Drain Valve Discharge Line (To Suitable Drain) (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 13: Operation

    • When the water is supplied from a water supply tank, the height of the tank and the diameter of the pipes and their relation to water pressure, should be taken into consideration. Gravity water pressure is not recom mended. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 14 NOTICE: The pipes MUST be completely drainable. If the hot water faucets are located at a point higher than the water heater, place a drain valve at the lowest point (see diagram to the left). (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 15 Compound used on the threaded joints of the gas piping must be of the type resistant to the action of propane gas. Use compound sparingly and use on male threads only. (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 16 If the relief valve on the system discharges periodically, this may be due to thermal expansion in a closed water supply system. Contact the water supplier or local plumbing inspector on how to correct this situation. Do not plug the relief valve. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 17 All vent components (adapters, pipe, elbows, terminals, etc.) should be UL 1738 Certified Stainless Steel Venting Material (e.g. AL29-4C). The specified vent termination must be used. The termination should be a 90° elbow type with screen. (Refer to page 18). (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 18 Board Inspection Hole#1 NOTICE : Vent pipes must be completely insulated with inflammable material when installed in alcoves, closets, and garages and must not touch any flammable material. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 19 Not following proper condensate procedures will void warranty. (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 20 (3m) horizontally Clearance above pave sidewalk or paved driveway located on public 7 ft (2.13 m) property Clearance under veranda,porch, 12 in (30 cm) deck or balcony (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 21 1/4” Per Feet Downward Slope 6” Clearance 12“ Minimum Support Hanger Vent Adapter To drain,dispose of condensate in accrdance to local codes 9.8“ 9.8“ Typical Horizontal Termination W1/4” Per Feet Downward Slope (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 22 • The MAXIMUM distance between the water heater and the remote control(s) installation location is limited to 50 feet. • No other manufacturer’s controls are suitable for use with this water heater. • DO NOT attempt to disassemble the remote control. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 23 Place the remote control against the wall, align the holes of control with the holes in the wall, and fasten them with wood thread screws. (See illustration below) (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 24 WARNING: Shock hazard line voltage is present. Before servicing the water heater, turn off the electrical power to the water heater at the main disconnect or circuit breaker. Failure to do so could result in severe personal injury or death. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 25 Heat Exchanger Protection Device of Water Intlet of Water Outlet Gas Proportion Valve(A) Section Valve C Section Remote Control Water Valve Valve (Optional) Gas Main Valve(B) Water Flow Sensor (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 26 Hot and Cold Pipe Insulation Installation .For increased energy efficiency, use pipe insulation. Please install the insulation, according to the illustrations above, making sure to insulate all the way to the top. Do not cover any drain or pressure valve(s). (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 27 • DON’T remove the front cover unless absolutely necessary. This should only be done after being examined by a qualified service technician. • DON’T install this product where standing water may occur. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 28 The installation hole in the wall needs to be sealed by fire-retardant material or wall thimble, making sure the water heater is tight and will not come off. Installation Hole Vent Pipe Back Installation Side Installation (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 29 Should you have any problems reading or following the instructions in this manual. STOP, and get help from a qualified service technican. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 30 TO TURN OFF GAS TO WATER HEATER is to be performed. NOTE: CA528 IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL CAMPLUX CONTENT IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.CAMPLUX.COM , CALL SERVICE HOT LINE (844) 538-7475 OR EMAIL TO SUPPORT@CAMPLUX.COM FOR MORE INFORMATION.
  • Page 31 About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1 1/2 seconds 155°F About 1 second Table courtesy of Shriners Burn Institute (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 32 NOTICE: If the BATH control ls turned on, the temperature setting on the MAIN control cannot be changed. The BATH control(s) will always have PRIORITY over the MAIN control. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 33: Maintenance

    Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem. (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 34 Water Filter 6 MONTH CLEANING ROUTINE To prevent water scale, lime or rust deposit buildup and ensure your Camplux tankless water heater is running as efficiently as possible it is highly recommended that you clean your Camplux tankless water heater every 6 months.
  • Page 35 Freezing will occur with no power. In very cold areas and when the temperature is under 32°F, or in event of an ice storm, freezing will occur as the heating power limit is exceeded.If these conditions take place, please follow the procedures explained below. (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 36 6. Open all hot water faucets. Before proceeding to the next step, make sure that COLD water is coming out of all hot water faucets. 7. To put the water heater back into operation after draining, follow the steps below. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 37: Troubleshooting

    This function is to purge to rotate after Normal operation. There is no need to call for unburned gas 10-15 hot water faucet service. Check for error code seconds is closed (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...
  • Page 38 CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 39: Replacement Parts

    • The model and serial number of the water heater from the rating plate. • Specify type of gas (natural or propane) as marked on the rating plate. • Part description (as noted below) and number of parts desired. (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 40: In The Box

    Gas Valve Assembly Heat Exchanger Protection Device Cold Water Temp. Sensor Anti-Freezer Auto Water Flow Adjust Device Thermostat Gas Inlet Anti-Freezer Thermostat Water Inlet Exhaust Collector Water Outlet Exhaust Outlet (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 41 All shipments of any type of product coming to Camplux for any reason must have an RGA for any repairs to be made. Please contact Camplux to obtain an RGA number prior to shipping anything to Camplux. Failure to do so could result in loss of product.
  • Page 42 Standard/Not Included Automatic 80-160℉ Temperature Control Automatic 90 -140℉ Automatic 80 -160℉ 1 Year Warranty 1 Year 1 Year 14.37*25.39*4.72 Inch Product Dimensions 15*6.5*22.24 Inch 12.8*20.28*5.91 Inch RESIDENTIAL SERIES (844) 538-7475 support@camplux.com 3330-A Marathon Ct Charleston, SC 29418 Visit Us: Camplux.com...
  • Page 44 (844) 538-7475 3330-A Marathon Ct Charleston, SC 29418 support@camplux.com Visit Us: Camplux.com...