Installation
Guide
r
Follow
the
procedure
below
to configure
the
thermostat
to match
the
installed
heating/cooling
system,
and
customize
feature
opemdon
as desired.
Function
Setting
N®[]_BB
number
To begin, press and hold the A and FAN
buttons until the display changes
Press A or Y to change settings
Press NaT to advance to next function
Press DaNE to exit and save settings
Setup Function
8 Emergency
heat
cycle rate (CPH)
9 Compressor
cycle rate (CPH)
10 Second stage
compressor
cycle
rate (CPH)
12 System setting
adjustment
Settings & Options
9
For electric
emergency
heat
1
For steam or gravity systems
3
For hot water systems & furnaces
of over 90% efficiency
5
For gas or oil furnaces
of less than 90% efficiency
)Other cycle rate options:
2, 4, 6, 7, 8, 10, 11 or 12 CPH)
Recommended
for
most
compressors
)Other cycle rate options:
1, 2, 4, 5 or 6 CPH)
Recommended
for most compressors
)Other cycle rate options:
1, 2, 4, 5 or 6 CPH)
0
Manual
changeover
(HeatlCool/Off)
1 Auto changeover
(Heat/Cool/Auto/Off)
**See page 14
2 Auto changeover
only (Auto) **See page 14
13
Adaptive
Intelli=
1
On **See
page
14
gent
Recove_
TM
O
Off
14 Temperature
0
Fahrenheit
display
1
Celsius
15 Compressor
protection
16 Schedule format
27
Heat temperature
range stops
28
Cool temperature
range stops
5
Five-minute
compressor
off time **See page 14
[Other options:
0, 1, 2, 3 or 4-minute
off time]
0
5/2 (pregremmable
weekdays
and weekends)
1
5/1/1 (weekdays, Saturday & Sunday programmable)
90
Highest heating temperature
setting
40-89 Heating temperature
range (increments
of 1 °F, or 0.5°C)
50
Lowest cooling
temperature
setting
51-99 Cooling temperature
range (increments of 1 °F, or 0.5°C)
12