Page 1
15216-MD-40-EVEN Mux/Demux Patch Panels Introduction This document explains how to install and operate the Cisco ONS 15216 100 GHz 40-channel mux/demux patch panel. The Cisco ONS 15216 40-channel mux/demux patch panel is a new ONS 15216 FlexLayer unit that allows 40-channels of ITU wavelengths to be placed onto a single fiber, and removes 40-channels of ITU wavelengths from a single fiber.
Cisco ONS 15216-MD-ID-50 Optical Interleaver and Deinterleaver Pluggable” guide. Safety Information Before you install, operate, or service the Cisco ONS 15216 100 GHz 40-channel mux/demux odd and even patch panels, you must read the Regulatory Compliance and Safety Information for Cisco Optical Transport Products document for important safety information and warning translations.
No electrostatic discharge (ESD) or other electrical safety considerations apply. Product Description The Cisco ONS 15216 40-channel mux/demux patch panel is a new ONS 15216 FlexLayer unit that allows 40-channels of ITU wavelengths to be placed onto a single fiber, and removes 40-channels of ITU wavelengths from a single fiber.
Check for external damage. Visually check all components and immediately Step 3 report any shipping damage to your customer service representative. Have this information ready: Invoice number of shipper (see packing slip) • Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 8
Use only the fastening hardware provided with the ONS 15216 patch panel to Caution prevent loosening, deterioration, and electromechanical corrosion of the hardware and joined material. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 9
ANSI bracket positions and also mentions the 40 mm position of the ETSI brackets. The 19-inch (482.6 mm) brackets are shown for reference in the following figures. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 10
40 mm Recess Location. Figure 3 6” , 6.5” and 40 mm Recess Location 6.01 6.54 REF [152,6] [166,2] 19˝ Bracket 19˝ Bracket 1.54 REF [39,2] 19˝ Bracket Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 11
Note ground position must be used. Figure 4 Ground positions on the Cisco ONS 15216 Patch Panel Lateral Ground Position Rear Ground Position Ground Lock Pan Head Washer Screw Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 12
Open the front panel to its maximum position. Figure 5 Cisco ONS 15216 Odd or Even Patch Panel (Closed Position) Front Panel Lockout Mechanism Front Panel Front Panel Lockout Mechanism Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 13
Pull the drawer holding the finger tab with the other hand. (See Figure Figure 6 Cisco ONS 15216 Odd or Even Patch Panel—Opened Front Panel and Drawer in the Recessed Position Drawer Finger Extraction Latch Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 14
Open the cable retention clip of the left or right fiber bend radius controller. (See Figure Route the cables through the left or right fiber bend radius controller. (See Figure Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 15
Cisco ONS 15216 Odd or Even Patch Panel—Opened Front Panel and Drawer in the Extracted Position Left Fiber Bend Radius Controller Right Fiber Bend Radius Controller Inventory USB Type A Receptacle Connector Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 16
Panel and Drawer in the Extracted Position Left Fiber Bend Radius Controller Drawer Finger Left USB Insertion Latch Cable Clamp Cable Retention Clip Foam Pad Right Fiber Bend Radius Controller Right USB Cable Clamp Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 17
LC-UPC II COM-TX Common output LC-UPC II Chi_RX Channel input LC-UPC II Chi_TX Channel output LC-UPC II MON-DMX Monitor port-demux section LC-UPC II MON-MUX Monitor port-mux section LC-UPC II Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 18
Figure 10 Figure 11 show the channel ID labels. Figure 10 shows the Channel ID label placed on the odd patch panel. Figure 10 Patch-Panel C-Band ID Label—Odd Module Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 19
Installation Figure 11 shows the channel ID label placed on the even patch panel. Figure 11 Patch-Panel C-Band ID Label—Even Module Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 20
Note likely to get dirty if they are capped when not in use. Because the procedure for a thorough cleaning of these adapters is complicated, Cisco recommends that you use a commercially available cleaning kit and closely follow the instructions included with the kit.
Page 21
Optical swab • Optical receiver cleaning stick • Using an inspection microscope, inspect each fiber connector for dirt, cracks, or Step 1 scratches. Replace any damaged fiber connectors. Step 2 Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 22
ONS 15454, use the electrostatic discharge wristband supplied with the ONS 15454. Plug the wristband into the ESD jack on the lower right front side of the ONS 15454. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 23
Figure 12. Single drawer configuration is shown for reference. 19 inch rack is shown for reference. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 24
19-inch (482.6-mm) rack is shown for reference. Figure 12 Single Drawer Configuration Rack Rack Left Left cable guide cable guide Right Right cable guide cable guide Rack Left cable guide Right cable guide Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 25
23-inch (584.2-mm) rack is shown for reference. Figure 13 Two Drawer Configuration Rack Rack Left Left cable guide cable guide Right Right Right cable guide cable guide cable guide Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 26
Diagram 3 in Figure 14 shows fiber protection provided by the upper cable guide for fibers routing upward. Figure 14 Fiber Protection Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 27
Diagram 2 of Figure 15 shows velcro and cable guide tied for a double drawer configuration. Figure 15 Velcro and Cable Tie Cable tie Velcro Cable tie Velcro Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Step 5 of the “Install Odd and Even Patch Panels” section on page 8. (See Figure 6 Figure Gently disconnect the fiber-optic connectors from the LC-LC adapters. Step 3 Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Units Short Term (96 hours/year) Temperature Celsius Range (STR) Fahrenheit Continuous Operative Temperature Celsius Range (OTR) Fahrenheit Power Handling for the Optical Port Power Handling for the USB Port Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Operating Bandwidth -0.50 dB Clear • any state of Bandwidth polarization (SOP) and -1.0 dB Clear within Bandwidth operative -3.0 dB Clear temperature Bandwidth range around ITU • center wavelength Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 31
Adjacent Channel any state of 17.0 • Isolation MUX polarization (SOP) and Non-Adjacent Channel 30.0 within Isolation MUX operative Total Crosstalk MUX 14.0 temperature range within • operating bandwidth Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Page 32
7. PDL (Polarization Dependent Loss) is defined as the difference between the maximum and minimum IL in the 100 GHz transmitted channel Bandwidth (Operating Wavelength Bandwidth) evaluated at all SOP, measured at a given wavelength. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
Cisco ONS 15454 DWDM Reference Manual • Cisco ONS 15454 DWDM Procedure Guide • Cisco ONS 15454 DWDM Troubleshooting Guide • Visit the End-of-Life and End-of-Sale Notices page for EOL and EOS announcements. Installing the Cisco ONS 15216-MD-40-ODD and 15216-MD-40-EVEN Mux/Demux Patch Panels 78-19053-01...
The RSS feeds are a free service and Cisco currently supports RSS Version 2.0. Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners.