5.8.3.1 MD area selection
Select AREA SEL. and press + or – button to enter
submenu. It will show as in Fig.5-12.
<< MD ZONE SETUP >>
ZONE
FUNCTION
SIZE SET
SAVE & EXIT
RETURN
<Fig.5-12 MD Zone Setup>
① MD Zone setting
This zone is effective when MD DISPLAY is FRAME.
ZONE
18
② Function setting
FUNCTION
③ MD frame size setting
Press + or – button to set MD frame size and position.
- set the MD frame size using direction buttons
(+,-,UP,DOWN)
- press MENU button in order to change the position.
- set the MD frame position using direction buttons.
- press the MENU button and hold for more than
2 seconds to exit size and position setting menu.
1
OFF
1 ~ 4
OFF  ON
5.8.4 Communication setting
In order to use remote control through RS-485, set the
values properly.
<< COMMUNICATION SETUP >>
CAMERA ID
1
BAUDRATE
9600
PROTOCOL
DEFAULT
SAVE & EXIT
RETURN
<Fig.5-13 Comm. Setup>
① Camera ID setting
CAMERA ID
0 ~ 255
② Baudrate setting
2400  4800  9600  19200
BAUDRATE
 38400  57600
③ Protocol setting
DEFAULT  PELCO  KD6  VCL
PROTOCOL