Battery; Integriertes Netzteil - Honeywell 026593.10 Mounting And Connection Instructions

Door module 12v dc, rs485/230v ac, rs485
Table of Contents

Advertisement

Mounting and Connection Instructions - Door module RS485
3.3

Battery

Space for a battery in the cover of the housing: 1 x Item no. 018 002
Fix the battery 12 V/2,0A (Item no. 018002) by means of a flexible "Dual Lock" Velcro fastening tape in the cover:
Cover with "Dual Lock" Velcro fastening tape
Stick one "Dual Lock" tape (Item no. 055 280) to the inside of the door module cover (see illustration) and one
"Dual Lock" tape to the battery.
Make sure that the surface is dry and free of grease.
Then press the battery on the Velcro fastening tape.
Use the red (+) and black/red (-) cable of the pcb for connecting the battery to the pcb.
The end-of-charging voltage of the battery charging unit is set in the factory for Sonnenschein batteries of the
A500 series. If it is necessary to change the setting, proceed as described in the chapter "Adjusting the
end-of-charging voltage".
3.4

Integriertes Netzteil

!
Fully electronic power supply/charging unit
!
Voltage regulated
!
Current limited
!
Redundancy standby operation
with battery monitoring
!
Total discharge protection
!
Charge monitoring
!
Battery failure detection
!
Up to 2Ah battery capacity
Mounting
Warning! Danger for man and / or device
Please note safety instructions!
Disconnect the unit from the power supply when installing the power supply.
battery 12V 2,0Ah
Cover with installed battery
11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

026594.10

Table of Contents