3-6-39
RP Head Sensitivity Detection (50M Mode)
Specification
Sensitivity 150+/-15 (mV/um)
Mode
Playback
Test Point
(1) ATF:TP732 (2) HSW:TP722(RP HSW) (not TP723(PB HSW) (3) GND:TG510
Adjustment
SERVO Adjustment Menu: "A05 RP GAIN ED"
Tape
VFM3581KM or VFM3581KL
Before this adjustment RP Head Sensitivity Adjustment (25M Mode) must be completed.
1. Select "A05 RP GAIN ED" in the Service Menu.
2. Playback a LISTA Alignment Tape (VFM3581KM).
3. Select LISTA Main Menu "(1) Sensitivity Measurement" Press enter when " 1.2% Speed..." is appeared to start
the Sensitivity measurement.
4. Confirm that the specification is satisfied when << Sensitivity Measurement Finish>> and " Sensitivity =
sensitivity value" are appeared.
Adjustment Value