Honeywell Bendix/King Silver Crown Plus Pilot's Manual page 39

Table of Contents

Advertisement

Another push of the mode button
will cause the unit to go into the
TIMER mode. See Figure 18.
FIGURE 18
Timer mode
When the unit is turned on the
elapsed timer begins counting
upwards from zero. The timer can be
stopped and reset to zero by pushing
the NAV frequency transfer button for
2 seconds or more causing the ET on
the display to flash. In this state the
timer can be set as a countdown timer
or the elapsed timer can be restarted.
The countdown timer is set by using
the NAV inc/dec knobs to set the
desired time and then pushing the
NAV frequency transfer button to start
the timer. The outer knob selects
minutes, the inner knob in the "in"
position selects ten second intervals,
and the inner knob in the "out"
position selects individual seconds.
After the countdown timer reaches
zero, the counter will begin to count
upwards indefinitely while flashing for
the first 15 seconds. Or the elapsed
timer can also be reset to zero and
started again after it has been
stopped and reset to zero by pushing
the NAV frequency transfer button.
The Audio Alert, if installed, is then
sounded.
The NAV ACTIVE and STANDBY
frequencies are stored in the memory
on power down and return on power
up.
When the smaller
increment/decrement knob is pushed
in, depressing the NAV TRANSFER
button will interchange the ACTIVE
KX 155A/KX 165A
and STANDBY frequencies. The NAV
IDENT knob is active in the pulled out
position so that both voice and ident
can be heard. When this knob is
pushed in, the ident tone is
attenuated. The volume of voice/ident
can be adjusted by turning this knob.
Pilot Configuration
This mode can be accessed by
pressing and holding the Nav Mode
Button for more than 2 seconds and
then pressing the Nav Frequency
Transfer Button for an additional 2
seconds, while continuing to hold the
Nav Mode Button. When the Pilot
Config Mode is entered the unit will
show the "SWRV" mnemonic which is
the unit software revision level.
Adjustment pages can be accessed
by MODE button presses.
The pilot may adjust two
parameters in the pilot configuration,
the display minimum brightness and
sidetone volume level.
Minimum Brightness (BRIM) will
have a range of 0 - 255. The dimmest
is 0 and the brightest is 255.
Sidetone volume level is adjusted
when SIDE is displayed. Values from
0 - 255 may be selected with 0 being
least volume, 255 being the greatest.
Subsequent presses of the
MODE button sequences through
SWRV, BRIM, SIDE, and then back to
SWRV.
Momentarily pressing the Nav
Transfer Button exits Pilot
configuration mode. The Nav returns
to its pre-Pilot Config state with the
new brightness and sidetone levels
stored in non-volatile memory.
Default Mode
Turning on the KX 155A or KX
165A while pressing either the COMM
 