HIKVISION DS-K1T671TM-3XF Manual
Hide thumbs Also See for DS-K1T671TM-3XF:

Advertisement

Temperature Screening MinMoe Configuration

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION DS-K1T671TM-3XF

  • Page 1 Temperature Screening MinMoe Configuration...
  • Page 2 CONTENTS  Introduction  Preparation  Installation  Local GUI Configuration  Operation  Q&A...
  • Page 3 Introduction -> System Structure Access control and temperature events can be managed by iVMS-4200 or HikCentral Professional. MinMoe touch-free temperature screening solutions UTP cable Switch Wall mounting & access control Entrance MinMoe temperature screening terminal - wall mounting Plug & play Entrance MinMoe temperature screening...
  • Page 4 Introduction -> Device Parameters DS-K1T671TM-3XF Sensor Vanadium Oxide uncooled sensor Resolution 120 × 160 Frame rate 25 fps Temperature measurement Temperature range 30 °C to 45 °C Temperature accuracy ±0.5 °C, without black body calibration Measuring distance 0.3 to 2.0 m...
  • Page 5 Introduction -> Device Parameters DS-K5604A-3XF/V DS-K1T671TM-3XF Plug & play LCD screen 10.1 inch 7 inch Face capacity 50,000 50,000 Card capacity 50,000 M1 cards Thermal imaging resolution 120 x 160 120 x 160 Temperature range and 30-45°C (±0.5 °C) 30-45°C (±0.5 °C)
  • Page 6 Introduction -> Device Parameters DS-KAB671-B (Optional) Material SPCC Weight 6.7 kg (14.8 lb.) Dimension (W x H x D) 98.5 mm × 1342 mm × 225 mm (3.9" × 52.8" × 8.9")
  • Page 7 Introduction -> Device Parameters DS-DM0710BL base bracket (Optional) Material SPCC Weight 6.7 kg (14.8 lb.) Dimension (W x H x D) 193 mm × 353.5 mm × 195.5mm (7.6'' × 14.3'' × 7.7'') Net Weight 2.2 ± 0.5 Kg (4.85 ± 1.1 lb) Gross Weight 2.5 ±...
  • Page 8 Introduction -> Device Parameters DS-KC001 monitoring tablet (Optional) Screen 7-inch Touch-Screen Display resolution 1024 * 600 Records quantity 100,000 Dimension (W x H x D) 200 mm × 140 mm × 15.5 mm (7.87" × 5.51" × 0.61") 419.3 g (without package) Weight...
  • Page 9 CONTENTS  Introduction  Preparation  Installation  Local GUI Configuration  Operation  Q&A...
  • Page 10 Preparation -> Site Selection Indoor and windless environment use only. Indoor environment temperature must be 10 ~ 35℃. If beyond this range, the temperature measurement accuracy of the device cannot be guaranteed. The device should be at least 2 meters away from the light, and at least 3 meters away from the window.
  • Page 11 Preparation -> Unbox Terminal Bracket Thermal MinMoe Terminal Accessories Quick Start Guide Quick User Manual...
  • Page 12 Preparation -> Unbox Floor Stand Pole Package Pole and accessories...
  • Page 13 Preparation -> Accessories and Tools Accessories for each terminal Qualified power adapter - 12V DC, 2A. LAN Cable. Gang box (optional). Tools Screwdriver set (Compulsory), wire stripper, impact drill, etc.
  • Page 14 CONTENTS  Introduction  Preparation  Installation  Local GUI Configuration  Operation  Q&A...
  • Page 15 Installation -> Terminal Wire Connection GND is the common interface for RS-485, exit button, and door contact sensor. If exit reader, touchless exit button, security unit, or lock is used, need to arrange a power adapter which can give enough power output for all of the devices.
  • Page 16 Installation -> Wall Mounting Drill holes on the wall and install gang box. Secure the mounting plate on the gang box and wall. Route the cables through the cable hole of the mounting plate, and connect to the corresponding external devices. Align the device with the mounting plate and hang terminal on the mounting plate.
  • Page 17 Installation -> Pole Mounting Install floor stand pole Unscrew the two screws on the side of the bottom cover and remove bottom cover. Install the expansion screws in the package into the holes at bottom. Make sure the expansion screw is slightly above the ground and secure it with nut.
  • Page 18 CONTENTS  Introduction  Preparation  Installation  Local GUI Configuration  Operation  Q&A...
  • Page 19 Keep everything the latest version. Firmware & iVMS-4200 Where to find the latest? UK PORTAL HIKVISION WEBSITE...
  • Page 20 Configuration -> Basic Settings Activate the device. Press on the screen for 3 seconds to input password and enter local menu. Check device Set IP address firmware version. Make sure it is the latest version. Firmware: http://www.hikvisioneurope.com/uk/portal/?dir=portal/Product%20Firmware/00%20Temperature%20Screening/Temperature%20MinMoe%20%28DS- K1T671TM-3XF%26DS-K5604A-3XF_V%29/firmware...
  • Page 21 Configuration -> Firmware explained UK PORTAL MinMoe terminal firmware Thermal module firmware MCU extension module* *normally no need to upgrade...
  • Page 22 Configuration -> Device Upgrading Upgrading Terminal firmware & Thermal camera Upgrading MCU...
  • Page 23 Configuration -> Temperature Settings...
  • Page 24 Configuration -> Temperature Settings If disable, terminal won’t detect temperature, it will work as a traditional access control terminal. When measured temperature is larger than Max. value or smaller than Min. value, alarms will be triggered. For calibration purpose. Please refer to calibration guide. Calibration is recommended once per year. To determine whether the abnormal temperature can open the door or not.
  • Page 25 Configuration -> Mask Settings...
  • Page 26 Configuration -> Mask Settings Anti-spoofing Smaller value -> larger authentication distance If disabled, terminal won’t detect a face with mask. Similarity level when terminal recognizes a face with mask. If enabled, terminal won’t open the door for the person without a mask. If enabled, terminal will prompt a visual reminder on the local screen for the person without a mask.
  • Page 27 Local Operation -> Log query...
  • Page 28 Local Operation -> Log query Support search log by person ID, card number and person name. Abnormal temperature will be marked as red.
  • Page 29 Local Operation -> Export records...
  • Page 30 Local Operation -> Export records Export authentication records to USB. (Default file name: Allevent.csv) Note: • The exported captured pictures are encrypted.
  • Page 31 A LITTLE BIT MORE…...
  • Page 32 CONTENTS  Introduction  Preparation  Installation  Configuration Daily Use Recommendation  Operation  iVMS-4200 Operation Q&A...
  • Page 33 Operation -> Daily Use Recommendation After Thermal MinMoe is powered on, • please wait for 90 minutes to warm up. Recommend to wait for 3 minutes • indoors (including walking indoors) to get the most accurate result. It is better to take off the hat after •...
  • Page 34 Thermal MinMoe + iVMS-4200...
  • Page 35 Basic Settings & Real-time monitoring...
  • Page 36 Operation -> iVMS-4200 Operation Face + Temperature mode Add device. Register person. Apply person. Check real-time events in the monitoring and receive quick pop up alarms Note: • When temperature is abnormal, device will trigger alarm output automatically, no need configuration.
  • Page 37 Operation -> iVMS-4200 Operation Temperature measurement only mode Real-time events in monitoring page Note: • In Temperature Measurement Only mode, only thermal image is taken for now.
  • Page 38 Operation -> iVMS-4200 Operation Configure terminal parameters Remote configuration Others Access Control parameters   If enabled, meaning temperature only mode; otherwise, authorized access mode Door not open when temperature is abnormal Must wear face mask Temperature alarm threshold...
  • Page 39 Search and Export Events...
  • Page 40 Operation -> iVMS-4200 Operation Search history events Note: • Select device type as Access Control to get temperature information. • Click Show More, to search event by person name, card No. etc.
  • Page 41 Operation -> iVMS-4200 Operation Export events Exported sample file: iVMS-4200 Exported Events iVMS-4200 Exported Events.csv Note: • Both images and temperature details can be exported.
  • Page 42 Alarm handling on iVMS-4200...
  • Page 43 Operation -> iVMS-4200 Operation -> alarm linkage...
  • Page 44 Operation -> iVMS-4200 Operation -> alarm linkage...
  • Page 45 Operation -> iVMS-4200 Operation -> alarm linkage related email setting...
  • Page 46 Operation -> iVMS-4200 Operation -> alarm pop up with more details...
  • Page 47 Operation -> iVMS-4200 Operation -> Event Types Other related event types: • No mask • Skin-surface temperature measured...
  • Page 48 Operation -> iVMS-4200 Operation -> quick alarm pop up...
  • Page 49 Others – T&A Records...
  • Page 50 Operation -> iVMS-4200 Operation -> T&A Records Note: • T&A rules need to be configured in advance.
  • Page 51 Thanks...

This manual is also suitable for:

Ds-k5604a-3xf/vDs-kab671-bDs-dm0710blDs-kc001

Table of Contents