Download Print this page
HIKVISION MinMoe DS-K1T671TM-3XF Configuration Manual
Hide thumbs Also See for MinMoe DS-K1T671TM-3XF:

Advertisement

Quick Links

Temperature Screening MinMoe Configuration

Advertisement

loading

Summary of Contents for HIKVISION MinMoe DS-K1T671TM-3XF

  • Page 1 Temperature Screening MinMoe Configuration...
  • Page 2 CONTENTS  Introduction  Preparation  Installation  Configuration  Operation  Q&A...
  • Page 3 Introduction -> System Structure Access control and temperature event can be managed by monitoring tablet, iVMS-4200 or HikCentral Professional.
  • Page 4 Introduction -> Device Parameters DS-K1T671TM-3XF Sensor Vanadium Oxide uncooled sensor Resolution 120 × 160 Frame rate 25 fps Temperature measurement Temperature range 30 °C to 45 °C Temperature accuracy ±0.5 °C, without black body calibration Measuring distance 0.3 to 2.0 m Working voltage 12 VDC/2 A 0 °C to 50 °C...
  • Page 5 Introduction -> Device Parameters DS-K5604A-3XF/V DS-K1T671TM-3XF Plug & play LCD screen 10.1 inch 7 inch Face capacity 50,000 50,000 Card capacity 50,000 M1 cards Thermal imaging resolution 120 x 160 120 x 160 Temperature range and 30-45°C (±0.5 °C) 30-45°C (±0.5 °C) accuracy Authentication Distance 0.3-2m...
  • Page 6 Introduction -> Device Parameters DS-KAB671-B (Optional) Material SPCC Weight 6.7 kg (14.8 lb.) Dimension (W x H x D) 98.5 mm × 1342 mm × 225 mm (3.9" × 52.8" × 8.9")
  • Page 7 Introduction -> Device Parameters DS-DM0710BL base bracket (Optional) Material SPCC Weight 6.7 kg (14.8 lb.) Dimension (W x H x D) 193 mm × 353.5 mm × 195.5mm (7.6'' × 14.3'' × 7.7'') Net Weight 2.2 ± 0.5 Kg (4.85 ± 1.1 lb) Gross Weight 2.5 ±...
  • Page 8 Introduction -> Device Parameters DS-KC001 monitoring tablet (Optional) Screen 7-inch Touch-Screen Display resolution 1024 * 600 Records quantity 100,000 Dimension (W x H x D) 200 mm × 140 mm × 15.5 mm (7.87" × 5.51" × 0.61") 419.3 g (without package) Weight...
  • Page 9 CONTENTS  Introduction  Preparation  Installation  Configuration  Operation  Q&A...
  • Page 10 Preparation -> Site Selection Indoor and windless environment use only. Indoor environment temperature must be 10 ~ 35℃. If beyond this range, the temperature measurement accuracy of the device cannot be guaranteed. The device should be at least 2 meters away from the light, and at least 3 meters away from the window.
  • Page 11 Preparation -> Unbox Terminal Bracket Thermal MinMoe Terminal Accessories Quick Start Guide Quick User Manual...
  • Page 12 Preparation -> Unbox Floor Stand Pole Package Pole and accessories...
  • Page 13 Preparation -> Accessories and Tools Accessories for each terminal Qualified power adapter - 12V DC, 2A. LAN Cable. Gang box (optional). Tools Screwdriver set (Compulsory), wire stripper, impact drill, etc.
  • Page 14 CONTENTS  Introduction  Preparation  Installation  Configuration  Operation  Q&A...
  • Page 15 Installation -> Terminal Wire Connection GND is the common interface for RS-485, exit button, and door contact sensor. If exit reader, touchless exit button, security unit, or lock is used, need to arrange a power adapter which can give enough power output for all of the devices.
  • Page 16 Installation -> Wall Mounting Drill holes on the wall and install gang box. Secure the mounting plate on the gang box and wall. Route the cables through the cable hole of the mounting plate, and connect to the corresponding external devices. Align the device with the mounting plate and hang terminal on the mounting plate.
  • Page 17 Installation -> Pole Mounting Install floor stand pole Unscrew the two screws on the side of the bottom cover and remove bottom cover. Install the expansion screws in the package into the holes at bottom. Make sure the expansion screw is slightly above the ground and secure it with nut.
  • Page 18 CONTENTS  Introduction  Preparation  Installation  Configuration  Operation  Q&A...
  • Page 19 Configuration -> Basic Settings Activate device. Press on the screen for 3 seconds to input password and enter local menu. Set IP address. Check device firmware version. Make sure it is the latest version. http://www.hikvisioneurope.com/uk/portal/?dir=portal/Product %20Firmware/00%20Temperature%20Screening/Temperature% 20MinMoe%20%28DS-K1T671TM-3XF%26DS-K5604A- 3XF_V%29/firmware...
  • Page 20 Configuration -> Firmware explained UK PORTAL MinMoe terminal firmware Thermal module firmware MCU extension module* *normally no need to upgrade...
  • Page 21 Configuration -> Device Upgrading Upgrading Terminal firmware & Thermal camera Upgrading MCU...
  • Page 22 Configuration -> Temperature Settings If disable, terminal won’t detect temperature, it will work as a traditional access control terminal. When measured temperature is larger than Max. value or smaller than Min. value, alarms will be triggered. For calibration purpose. Please refer to calibration guide. Calibration is recommended once per year. To determine whether the abnormal temperature can open the door or not.
  • Page 23 Configuration -> Mask Settings If disabled, terminal won’t detect face masks. 1:N security level when terminal recognizes a face with mask. If enable, terminal won’t open the door for the person who doesn’t wear a face mask. If enable, terminal will give remind on local screen for the person who doesn’t wear a face mask. Note: Face mask detection is done by the algorithm which is running in terminal itself.
  • Page 24 Configuration -> Review Use software to upgrade device. Use device local screen to configure temperature and face mask. Configurations Terminal Local Screen iVMS-4200 HCP Pro Activate device √ √ √ IP Configuration √ √ √ Temperature setting √ √ √ Face mask setting √...
  • Page 25 Configuration -> Settings in HCP In HPC web client, physical view, device parameters, maximum and minimum temperature can be configured.
  • Page 26 CONTENTS  Introduction  Preparation  Daily Use Installation  Local Operation Configuration  Operation iVMS-4200 Operation  Q&A HCP Operation Software Comparison...
  • Page 27 Operation -> Daily Use After Thermal MinMoe is powered on, • please wait for 90 minutes to warm up. Recommend to wait for 3 minutes • indoors (including walking indoors) to get the most accurate result. It is better to take off the hat after •...
  • Page 28 Operation -> Local Operation Temperature measurement only mode. By default Enable Temperature Measurement Only. Enable Door Not Open When Temperature is Abnormal. Temperature Measurement Only Authentication Result Normal Temperature Abnormal Temperature Local Screen Door Access √ × Mark Attendance × ×...
  • Page 29 Operation -> Local Operation Temperature + mask checking mode. Enable Temperature Measurement Only. Enable Door Not Open When Temperature is Abnormal. Enable Must Wear Face Mask. Temperature + Mask Checking Mask OK Mask OK Mask NO Mask NO Authentication Result Temperature OK Temperature NO Temperature OK...
  • Page 30 Operation -> Local Operation Face authentication mode (without temperature measurement) Disable Temperature Detection. Disable Face with Mask Detection. Device works as a traditional access control terminal. Face Authentication Only Authentication Result Face authenticated Face authentication failed Local Screen Door Access √...
  • Page 31 Operation -> Local Operation Face + temperature authentication mode. If disable Door Not Open When Temperature is Abnormal, door access and attendance will be the same with pure face authentication. Below table shows the result when enable Door Not Open When Temperature is Abnormal.
  • Page 32 Operation -> Local Operation Face + temperature + mask authentication mode. If only give remind of wear mask, the door access and attendance will be the same with Face + temperature authentication. Below table shows the results of enable Must Wear Face Mask and enable Door Not Open When Temperature is Abnormal.
  • Page 33 Operation -> Local Operation Face + temperature + mask authentication mode. If only give remind of wear mask, the door access and attendance will be the same with Face + temperature authentication. Below table shows the results of enable Must Wear Face Mask and enable Door Not Open When Temperature is Abnormal.
  • Page 34 Operation -> Local Operation Log query. Support search log by person ID, card number and person name. Abnormal temperature will be marked as red. Note: • Only registered persons’ authenticated record can be searched from device local screen. • Records of strangers and Temperature Measurement Only can’t be searched from local screen.
  • Page 35 Operation -> Local Operation Export authentication record to USB. (Default file name: Allevent.csv) Export captured image to USB. (Default folder name: acsLinkCap) Note: • The exported captured pictures are encrypted. • Event Type MINOR_TEMPERATURE_CHECK means this event is Temperature Measurement Only.
  • Page 36 Thermal MinMoe + iVMS-4200...
  • Page 37 Operation -> iVMS-4200 Operation Face + Temperature mode Add device. Register person. Apply person. Check real-time event in the monitoring Note: • When temperature is abnormal, device will trigger alarm output automatically, no need configuration. (Not able to disable) • Device will upload normal image and thermal image both to iVMS-4200 after face is authenticated.
  • Page 38 Operation -> iVMS-4200 Operation Temperature measurement only mode Real-time event Note: • In Temperature Measurement Only mode, only thermal image is there in iVMS-4200.
  • Page 39 Operation -> iVMS-4200 Operation Configure terminal parameters Remote configuration Others Access Control parameters   Temperature only Door not open when temperature is abnormal Must wear face mask Over-temperature alarm value...
  • Page 40 Operation -> iVMS-4200 Operation Search history event Note: • Select device type as Access Control to get temperature information. • Click Show More, to search event by person name, card No. etc.
  • Page 41 Operation -> iVMS-4200 Operation Export event Exported sample file: iVMS-4200 Exported Events iVMS-4200 Exported Events.csv Note: • Both images and temperature details can be exported.
  • Page 42 Operation -> iVMS-4200 Operation Note: 1. No temperature overlay on captured image. 2. Normal camera capture image resolution is 768x432 (W x H). 3. Thermal camera capture image resolution is 120x160 (W x H). 4. Thermal camera doesn’t support live view.
  • Page 43 Operation -> iVMS-4200 Operation -> alarm linkage...
  • Page 44 Operation -> iVMS-4200 Operation -> alarm linkage...
  • Page 45 Operation -> iVMS-4200 Operation -> alarm linkage related email setting...
  • Page 46 Operation -> iVMS-4200 Operation -> alarm pop up...
  • Page 47 Operation -> iVMS-4200 Operation -> Event Types Other related event types: • No mask • Skin-surface temperature measured...
  • Page 48 Thermal MinMoe + Hikcentral Pro...
  • Page 49 Operation -> HCP Operation Install HCP server & control client. Add terminal to HCP. Add persons to HCP. Create access level, access group. Apply persons to terminal. Login control client. Check real time event. Monitoring-Surveillance. Note: • Click Access Control to get temperature and mask information.
  • Page 50 Operation -> HCP Operation Check real time event. Door and Elevator-Surveillance.
  • Page 51 Operation -> HCP Operation Search history access record. Identity Access Search-Investigation. Export access record. Exported sample file: HCP Exported Access Record (With Remark)
  • Page 52 Operation -> HCP Operation Event function. In event settings, we can linkage alarm output, trigger email alert. Exported sample file: HCP Exported Event (With Remark) Note: • If only want to get temperature or mask details, suggest to use Identity Access Search.
  • Page 53 Operation -> HCP Operation Temperature and mask analysis. Search analysis result (Histogram) Note: • Support daily, weekly, monthly and custom time period to generate report. • Click No Mask can hide or display no mask person quantity. • It only count the persons registered in HCP.
  • Page 54 Operation -> HCP Operation Temperature and mask analysis. Search analysis result (Line chart) Note: • Different department can be selected.
  • Page 55 Operation -> HCP Operation Temperature and mask analysis. Export analysis result. Exported sample file: HCP Exported Skin-surface Temperature Analysis (With Remark) Note: • Export operation will export all the data searched on the left (marked in blue). Not just export the displayed data on the right.
  • Page 56 Operation -> HCP Operation Automatically update person‘s temperature in person list. After device upload new temperature to HCP, related person’s temperature will be updated in 3 minutes. Temperature status can be used to filter persons. Note: • From step 1 to step 12, all the mentioned operations are supported without license.
  • Page 57 Operation -> HCP Operation Alarm pop up Note:  Searching history alarm and exporting alarm images are same with Event function in step 10.
  • Page 58 Operation -> HCP Operation Attendance function. Records and Handling. Exported sample file: HCP Web Client_Records and Handling_Exported Raw Data Note: • Attendance function is only supported in Web Client. • The temperature showing in attendance is the latest temperature of each person when HCP calculates attendance result.
  • Page 59 Operation -> HCP Operation Attendance function. Export Report. Exported sample file: HCP Web Client_Export Report_Daily Report Note: • For all the attendance reports, temperature information only exists in Daily Report. • In daily report, maximum can select 1 month time period to export report.
  • Page 60 Operation -> HCP Operation Note: • No matter face authentication succeed or failed, device will always upload both normal image and thermal image to HCP. But HCP only displayed normal camera image. • For card authentication event, no matter succeed or failed, MinMoe terminal only uploads thermal image to HCP.
  • Page 61 Operation -> Software Comparison Ability comparison Functions iVMS-4200 HCP without License HCP with License Camera channels Depends on license Door number Depends on license Person quantity for access control 3200 50,000 50,000 Face template quantity for access control 3200 50,000 50,000 Person quantity for attendance 3200...
  • Page 62 Operation -> Software Comparison Function comparison (Basic) Below table shows the functions which has no relationship with license. Functions iVMS-4200 HCP without License HCP with License Get thermal camera captured image after face authentication √ Get normal camera captured image √...
  • Page 63 Operation -> Software Comparison Function comparison (License related) Below table shows the functions which is related to license. Functions iVMS-4200 HCP without License HCP with License Abnormal temperature trigger pop up alarm √ √ (Base module) Export temperature information in attendance daily report √...
  • Page 64 CONTENTS  Introduction  Preparation  Installation  Configuration  Operation  Q&A...
  • Page 65 Q & A Q1 – Can this temperature screening access control terminal support ℉? No, doesn’t support. Q2 – If face is authenticated, but temperature is abnormal, will terminal send card number by Wiegand to third party controller? No. Only when person identity is authenticated, and door is open, then, terminal will send card number by RS485 or Wiegand interface.
  • Page 66 Thanks...

This manual is also suitable for: