A.9 DS93 Write command
A.9

DS93 Write command

Write structure of data set 93 command
Byte Content
0 Coordination
1 Reserved
2 Reserved
3 Reserved
4 Number of
commands
5 Command 1
6 Command 2
7 Command 3
8 Command 4
9 Command 5
Assignment of command to command number and their meaning (byte 5 to 9)
Object
Command
number
number
0 0
703 1
709 4
711 5
707 10
708 11
190
Value / value range
0x31
0x00
0x00
0x00
Command
1 ... 5
Command number
Command number
Command number
Command number
Command number
Command
Reserved
Trip reset
Automatic mode
Manual bus mode
Parameters disabled
CPU/master ON
Parameters disabled
CPU/master OFF
Meaning
Write via acyclic bus channel
-
-
-
Number of subsequent valid commands
Optional; for meaning see the following table
Optional; for meaning see the following table
Optional; for meaning see the following table
Optional; for meaning see the following table
Optional; for meaning see the following table
Meaning
No function
Resets and acknowledges error messages
Transition to automatic mode (control by DP master)
Transition to manual mode. The motor starter switches to
manual bus mode depending on the interface via which the
command is received.
Parameterization by parameterizing master not possible, or
its parameters are ignored
Parameterization by parameterizing master is possible