Checking before Installation

Following shows requirements for the installation site.
It is desirable to see the installation site in advance before
carrying the machine to the user's site.
Check When Connecting the
Power Plug to an Outlet
1. When connecting the power plug of this equipment to an
outlet, be sure to use an outlet of a system different from
that of the host machine.
2. Be sure to install this equipment near an outlet so that
the power plug can be disconnected right away in case
of emergency, and do not put anything around the power
plug.
Checking the Installation
Environment
1. The environment of the installation site must be in
the range as shown below. Avoid installation near
the faucet, water boiler, humidifier or refrigerator.
• Guaranteed range for operation/image
Temperature: 10.0 to 30.0 deg C, Humidity: 20 to
80%
2. The machine must not be installed near a source of
fire or in an area subject to dust or ammonium gas.
If the area is exposed to direct rays of the sun,
provide curtains to the window.
3. Be sure to provide adequate ventilation of the room
to keep the work environment comfortable. Room
odor can be bothering when running the machine for
a long time in a poorly-ventilated room although the
ozone amount generated while running this
equipment does not harm human health.
Checking the Installation
Space
1. Be sure that the feet of this machine are properly set.
In addition, be sure to keep the machine horizontal.
2. Be sure to keep 100mm or more distance from the
wall to make enough room for performing the
operation.
• When options are not installed
• When the Booklet Finisher and Paper Deck Unit
are installed.
3. To install the host machine, install it in a well
ventilated place. Especially when there are multiple
host machines, be sure to locate the machine where
the machine is free from direct exhaust of other
machines. Be sure to keep the machine away from
the air-inlet duct which is used for ventilation of the
room.
• When options are not installed.
100mm or more
500mm or
more
• When the Inner Finisher and Paper Deck Unit are
installed.
100mm or more
500mm or
more
• When the Inner Finisher, Inner Hole Puncher and
Paper Deck Unit are installed.
100mm or more
500mm or
more
876
9. Installation
500mm or
more
1,094mm
500mm or
more
1,345 mm
500mm or
more
1,440 mm