Honeywell Bendix/King KX 165A Maintenance Manual page 72

Nav/comm transceiver
Table of Contents

Advertisement

BENDIX/KING
SERIAL NUMBER _____________________
A. CONTROL FUNCTIONS AND FREQUENCY ERROR
1. Transmitter Frequency Error:
The unit must have been turned off for at least one hour and allowed to stabilize at room
temperature (22
be 1 ppm or better.
When transmitting at 126.50 MHz, the frequency error shall be NMT ±122 Hz
** When transmitting at 126.510 MHz, the frequency error shall be NMT ±122 Hz
(relative to 126.50833 MHz).
If alignment is required, see
2. Display: _____________________ OK
3. Transfer Switches
4. Frequency Controls:
Increment Decrement
Roll over Characteristics
COMM MHz (136 to 118 MHz)
COMM MHz (.975 to .000 kHz)
**COMM MHz (.990 to .000 kHz)
NAV MHz (117 to 108MHz)
NAV kHz (.95 to .00 kHz)
Page 5-24
TEST DATA SHEET
The term "OK" indicates that a particular function is
operating properly.
±
2°C) immediately prior to testing. The frequency counter accuracy must
paragraph 5.2.2.2.1.
NAV: ______________ OK (Switches from an active to standby freq.)
COMM: ______________ OK (Switches from an active to standby freq.)
15610M00.RCD
NOTE
______ Hz error
______Hz error
Roll under Characteristics
(118 MHz to 136 MHz) ______ OK
(.000 kHz to .975 kHz)
(.000 kHz to .990 kHz)
(108 MHz to 117 MHz)
(.00 kHz to .95 kHz)
KX 165A
__________OK
__________OK
__________OK
__________OK
Rev 0, Jun/2000