Trouble shooting guide for New ECR model
MODEL: CE-6000, CE-6100, CE-7000, TK-6000, TK-7000, TK-6500, TK-7500
< CONTENS >

1. Flowchart for trouble shooting procedures

2-4. Normal diagnostic operation
3-1. How to remove the IC
3-2. Preparation for mounting the new IC
3-3. How to fix the IC
3-4. Cleaning after mounting the IC
1. Flowchart for trouble shooting procedures
2-3. IPL
Loading
2-4. Normal
diagnostic
Result

START

2-1. Mask
diagnostic
OK
Result
ti
NG
OK
Main P.C.Board 2
END
- 1 -
NG
2-2. Repair the
Main P.C.Board 1
2-5. Repair the
INDEX
Trouble shooting ECR V1.01

Advertisement

Table of Contents
loading

Summary of Contents for Casio CE-6000

  • Page 1 INDEX Trouble shooting ECR V1.01 Trouble shooting guide for New ECR model MODEL: CE-6000, CE-6100, CE-7000, TK-6000, TK-7000, TK-6500, TK-7500 < CONTENS > 1. Flowchart for trouble shooting procedures 2. Trouble shooting procedures 2-1. Mask diagnostic operation 2-2. Repair the Main P.C.Board 1 2-3.
  • Page 2 Trouble shooting ECR V1.01 2. Trouble shooting procedures 2-1. Mask diagnostic operation The model CE-6000/7000 series and TK-6000/7000 series have the Mask diagnostic operation in the machine. The following test can be checked in the Mask diagnostic operation. 1) Flash ROM data erase after write test 2) RAM read after write test To start the Mask diagnostic operation, perform the following operation.
  • Page 3 Trouble shooting ECR V1.01 Special error message : Fatal error code FErr20 Unfixed address is selected and unsettled error is happened. FErr26 Abruption of program working. The interruption of abnormal condition ( Watch dog ) is happened. FErr27 Stack pointer address become the except RAM address area. Note : If this error is happened, the Flash ROM program and data is damaged.
  • Page 4 Trouble shooting ECR V1.01 2-2. Repair the Main P.C.Board 1 To repair the No display machine, perform the following repair procedure. START 2-2-1. Repair around the power supply. Check around the power supply. 2-2-2. Repair procedure 1 Check osillation of the pulse signal correct.
  • Page 5 Trouble shooting ECR V1.01 2-2-1. Repair around the power supply 1) Check AC input voltage by a multimeter tester. 2) Check the voltage from each output pins of connector CN1 from the power supply PCB. CN1 Pin No.1 — VC1(DC32.3V) :For the Display power CN1 Pin No.2 —...
  • Page 6 Trouble shooting ECR V1.01 3) Check the DC/DC convertor in display PCB. [DC/DC convertor circuit for 7 segment Display Tube at Display PCB E445B-E2] Signal at Q3 position Signal at VF1 position [DC/DC convertor circuit for Dot Display Tube at Display PCB E445B-E2] Signal at Q2 position Signal at VD1 position Signal at D2 position...
  • Page 7 Trouble shooting ECR V1.01 2-2-2. Procedure Repair 1 1) Check that contact of CPU defective. ( For example, pin of CPU is floating. ) 2) Check that the power supply is supplied to CPU. ( For example, the cables between the CPU and the power supply are snapping. ) 3) Check “X1”...
  • Page 8 Trouble shooting ECR V1.01 3) Check the poor connection between CPU and RAM or Flash ROM1. Specially, check the Flash ROM1 connection to re-solder the all lines. 4) Check the RAM1 or Flash ROM1 chip enable signal. 5) If the signals of the address bus and the data bus are not stable (Ex: After some time, the all signal becomes GND level or so on.), replace “IC10”...
  • Page 9 Trouble shooting ECR V1.01 [ RAM1 chip enable signal ] RAM1 chip enable RAM Chip enable signal RAM1 IC3 RAM1 chip enable Pin No.22 RAM1 Data bus D0 RAM1 Address bus A0 RAM1 chip enable RAM1 chip enable Pin No.4 IC30 (74LV02) - 9 -...
  • Page 10 Trouble shooting ECR V1.01 2-3. IPL loading ( Initial program loading opertion ) After preforming the MASK diagnostic operation, it is necessary to dawn load the IPL data. To start the IPL loading, perform the following opertion. [In case of using the P/C communication] START Turn off the power switch and set the Mode switch to PGM position.
  • Page 11 Trouble shooting ECR V1.01 [In case of using the Memory Cassette RAC-9] START Turn off the power switch and set the Mode switch to PGM position. While pressing the reset switch and <JOURNAL FEED> button, turn the power switch on. Release the reset switch first and then release the <JOURNAL FEED>...
  • Page 12 Trouble shooting ECR V1.01 2-4. Normal diagnostic opertion The following test can be checked in the diagnostic test. 1) Key code test 2) switch status test 3) Individual function test START To START Normal diagnostic operation, refer to the "SERVICE MANUAL". 2-5.
  • Page 13 Trouble shooting ECR V1.01 2-5. Repair the Main P.C.Board 2 START < Probable Causes > 1.Display tube is broken. 2.Communication lines or data between Display the display and the Main P.C.Board have a problem caused a poor connection or a some IC broken. 1.Button or Key switch is broken.
  • Page 14 Trouble shooting ECR V1.01 3. The example of repair 3-1. How to Remove IC 5) IC clamps the location where there 1) Warm IC by hotblow. is not pin with tweezers. 2) Warm all pins of IC generally. 6) Remove IC slowly, while confirming whether solder is melting.
  • Page 15 Trouble shooting ECR V1.01 3-2. Preparation of solder for IC 1) Old solder is remaining, to the location 5) New IC is put on P.C.B. that removed IC yet. At this time, that the pin of IC does not First this old solder is removed. deviate from the pattern.
  • Page 16 Trouble shooting ECR V1.01 3-3. Solder IC 5) “2)” to “4)” of work are repeated. 1) Much solder is soldered to all pins of IC. After that become above photograph. 6) In the case that a little of solder remains, 2) Solder iron is slid in the left end from the remove it by using the desoldering right edge of IC like above photograph.
  • Page 17 Trouble shooting ECR V1.01 3-4. Clean around IC 1) Rosin is remaining, to the location that 3) Rosin is removed carefully by using soldered IC. alcohol and cotton applicator. 2) Ethyl alcohol is used, to remove rosin. 4) After that around IC becomes clean like above photograph.
  • Page 18 Trouble shooting V1.01 : Correction of page lines for Miss print CASIO TECHNO CO.,LTD. Overseas Service Division Nishi-Shinjuku Kimuraya Bldg. 1F 5-25, Nishi-Shinjuku 7-Chome Shinjuku-ku, Tokyo 160-0023, Japan...