UL Commercial Fire Installation
For UL864 Commercial Fire Installations, you will need to purchase separately the "5800BOX" (in which the
circuit board will be installed). Follow the instructions below and refer to Figure 5.
1. Mount the rear half of the 5800BOX directly to the wall in the selected location, hinged side up. Secure
using the 4 screws provided and insert screw in tamper tab, refer to Installation, step 3c and Fig. 3.
2. Thread the ECP wire through the conduit and feed through the opening at the side of the box rear.
3. Remove the circuit board from the 5881EN case and discard case. Install the circuit board into the
5800BOX and secure using the 4 screws provided. Install each antenna, refer to Installation: Step 6.
4. Connect the ECP terminals as shown.
5. Insert slots on top of box cover into hinges on top of box back and secure using 2 cover securing screws.
ENCRYPTED KEYS
The receiver can support up to 16 encrypted wireless transmitters (keys) at one time. The GREEN LED located on the receiver's circuit board may be used to determine how many
more encrypted keys may be enrolled into the receiver. This LED is also used to indicate when encrypted keys may be deleted. To determine how many more encrypted keys may be
enrolled and/or to delete enrolled encrypted keys:
1. Remove power from the receiver and set DIP switch 1 to the ON position.
2. Apply power to the receiver and watch the GREEN LED. You will see one of the following indications:
a. The GREEN LED blinks the number of spaces that are free for additional encrypted key enrollment and then goes to constantly ON.
b. The GREEN LED is constantly ON, indicating the receiver is full.
c. The GREEN LED is OFF, indicating no encrypted keys are enrolled.
3. If you do not want to delete any enrolled encrypted keys, advance to step 4. If you want to delete enrolled encrypted keys, wait until the GREEN LED is constantly ON in step 2 a. or
2 b. above and then:
a. Record the positions of DIP switches 1 through 5.
b. Set DIP switches 1 through 5 to the opposite positions of their current settings and wait a few moments.
c. Set DIP switches 1 through 5 back to their original positions as recorded in step a. All enrolled encrypted keys will be deleted.
Place DIP switch 1 back into the OFF position to return to normal receiver operation.
4.
NOTE: WHEN CIRCUIT BOARD IS
MOUNTED IN CONTROL'S CABINET,
GROUNDING LUGS (2) PROVIDED
MUST BE INSERTED IN LEFT-HAND
TERMINALS OF ANTENNA BLOCKS
AND SECURED TO CABINET (SEE
RECEIVER'S AND CONTROL'S
INSTRUCTIONS). WHEN BOARD IS
MOUNTED IN A SEPARATE CABINET
(COMMERCIAL FIRE APPLICATION),
DO NOT USE THE GROUNDING LUGS.
TO RELEASE CIRCUIT BOARD, BEND
BACK BOTTOM TABS (2). FOR
COMMERCIAL FIRE APPLICATION.
USE TWO SCREWS (NOT SUPPLIED)
WITH INSULATING WASHERS BENEATH
THE HEADS. TO MOUNT BOARD IN
SEPARATE CABINET. (SEE RECEIVER'S
INSTRUCTIONS).
SPECIFICATIONS
5881EN SERIES
INPUT VOLTAGE: 12VDC
CURRENT: 60mA
5881ENL
5881ENM
NOTES:
5881ENH
WHEN AN ENCRYPTED TRANSMITTER IS SUCCESSFULLY ENROLLED, LED FLASHES THE
NUMBER OF TIMES THAT IS EQUAL TO THE SPACE AVAILABLE FOR ADDITIONAL ENCRYPTED
KEYS. THE GREEN LED IS ALSO USED WHEN CHECKING ENCRYPTED KEY SPACE AVAILABLE
5881ENHC
AND PERFORMING DELETIONS.
SPECIFICATIONS
Dimensions:
7-3/8" W x 4-3/8" (10-7/8" w/antenna) H x 1-7/16" D
188mm W x 112mm H (277mm w/antenna) x 37mm D
5800BOX:
10.86 W x 5.41 (11.9 w/antenna) H x 2.24 D
276mm W x 137.5mm H x 57mm D
Input Voltage: 12VDC (from control's keypad terminals)
Current:
60mA (typical)
Operating Temperature: 0-50° C
Interface Wiring: RED: 12VDC input (+) Aux. Power / GREEN: Data Out to Control
YELLOW: Data In from Control / BLACK: Ground (–)
For Limitations of the entire alarm system, refer to the control panel's installation guide with which this device is used.
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could
void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause
interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15
of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
If using an indoor antenna, have a quality outdoor antenna installed.
Reorient the receiving antenna until interference is reduced or eliminated.
Move the radio or television receiver away from the receiver/control.
Move the antenna leads away from any wire runs to the receiver/control.
Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
Consult the dealer or an experienced radio/TV technician for help.
Federal Communications Commission (FCC) Part 15
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
For the latest documentation and online support information, please go to:
ÊN7635-3V5GŠ
N7635-3V5 1/16 Rev. A
CIRCUIT
BOARD
MOUNTING
HOLE
DIP
SWITCH
MOUNTING
HOLE
GREEN LED: NORMALLY OFF
ONE SHORT FLASH - RF MESSAGE DECODED
ONE LONGER FLASH - COMMAND RECEIVED FROM CONTROL
FOUR FLASHES - ENCRYPTED TRANSMITTER SUCCESSFULLY ENROLLED
Summary of Connections Diagram
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
SUPPORT & WARRANTY
https://mywebtech.honeywell.com/
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa.
For patent information, see
www.honeywell.com/patents
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2004 Honeywell International Inc.
USE MAX. OF 220 ft. (67m) OF #22 (0.64mm)
ANTENNAS
WIRE OR 550 ft. (168m) OF #18 (1mm) WIRE
INSERT IN
FOR EACH RUN. 20 ft. MAX. IN COMMERCIAL
RIGHT-HAND
FIRE INSTALLATIONS. (SEE RECEIVER'S
TERMINALS
INSTRUCTIONS N7635-3V5 DTD 1/16).
YELLOW
TO CONTROL'S KEYPAD
RED
TERMINALS. EACH
BLACK
RECEIVER MUST BE ON
GREEN
INDIVIDUAL HOME RUN.
WIRING OPENING
INTERFERENCE
INDICATOR LED
PLUG & SOCKET
SEE DETAIL A
DETAIL A
FRONT AND REAR TAMPER
5881ENHC ONLY
NFPA-72 COMPLIANT
Range: 200ft (60m) nominal indoors from wireless transmitters (the actual range to be
determined with the security system in the Test mode).
Receiver Sensitivity & Noise Rejection:
Receiver sensitivity and noise rejection are dynamically adjusted to match ambient
conditions. Unacceptably high noise levels or low signal levels are indicated at the control
panel. For test procedure, refer to the Installation & Setup Guide for the control panel with
which this device is used.
NFPA-72 Compliant
MyWebTech
www.honeywell.com/security
5800BOX
MOUNTING
HOLES
4 (TYP)
MACHINE
SCREWS
4 (TYP)
COVER
SECURING
SCREWS
Figure 5: 5881ENHC UL Commercial Fire Installation
NOTES
1. FOR DRY INDOOR USE ONLY.
2. DO NOT INSTALL IN AIR-HANDLING SPACES.
3. ALL CIRCUITS ARE SUPERVISED AND POWER LIMITED.
UL NOTES
1. NO MORE THAN ONE (1) WIRE PER TERMINAL MAY BE
CONNECTED.
2. ALL POWER-LIMITED WIRING MUST BE SEPARATED FROM
NON-POWER LIMITED AND HIGH-VOLTAGE WIRING BY
1/4" (6.4mm).
DIP SWITCH #5
ON:
FOR USE IN COMMERCIAL FIRE APPLICATIONS.
(SEE THE RECEIVER'S INSTRUCTIONS).
OFF:
USE IN NON-COMMERCIAL FIRE INSTALLATIONS.
DIP SWITCH: WHITE AREAS = SWITCH HANDLES
POSITION 2-4: DETERMINE RECEIVER'S ADDRESS
FRONT OF PC BOARD
CONSULT CONTROL'S INSTRUCTIONS FOR ADDRESS TO USE.
DIP SWITCH BELOW SHOWN SET FOR ADDRESS "0".
BACK OF PC BOARD
RECEIVER ADDRESS SETTINGS
SWITCH
("—" means "OFF")
ON
OFF
POSITION
0
1
2
3
4
5
5
(SEE TEXT ABOVE)
4
4
ON
ON
3
3
ON
ON
2
2
ON
1
1
MUST BE IN OFF POSITION
Patents
Warranty
FRONT TAMPER
(REAR TAMPER)
ECP
CONNECTION
PLASTIC
CONDUIT
5881-5800Box
5
6
7
ON
ON
ON ON
ON ON ON
5881EN-SOC-V8

Advertisement

loading