ADEMCO 5881EN Series RF Receiver – Installation Instructions
INTRODUCTION
The 5881EN RF Receiver is designed for use with control panels that support an RF receiver connection via the keypad terminals.
The 5881EN Series Receivers recognize alarm, status, and keypad control messages from
wireless transmitters operating at 345MHz.
One or two individually identified receivers can be employed, depending on the control
used. Connection of multiple receivers to a control can provide redundant coverage or
extend coverage in large area.
The 5881EN features a Spatial Diversity system that virtually eliminates the possibility of
"Nulls" and "Dead Spots" within the coverage area.
The 5881EN uses ADEMCO's High Security technology, and can be used in commercial
fire installations.
The 5881ENHC receiver contains front and back tamper that permits its use in commercial
burglary and fire installations.
U L
For 5881ENHC Receivers:
In commercial fire applications, the receiver can only be used with control panels that are
approved for use in Commercial Fire Installations. When the 5881ENHC is used in
commercial fire applications, DIP switch 5 must be in the ON position.
• In commercial burglary applications, the 5881ENHC can only be used with control panels that
are approved for use in Commercial Burglary Installations.
• In commercial fire applications, a keypad must be connected to Keypad Port 2 in the control.
The keypad must be mounted on the control or within 3 feet of the control with the wiring
encased in conduit.
• All power-limited wiring must be separated from non-power limited and high-voltage wiring by
¼" (6.4mm).
If a receiver is connected to a system in which more than the permitted number of wireless zones have been programmed, a "SET UP ERROR" message (on alpha keypads) or an "E4" or
"E8" message (on fixed-word keypads) will be displayed on the system's keypad, and none of the zones will be protected.
The instruction manual that accompanies the control includes recommendations regarding receiver and transmitter locations, the types of wireless zones that can be programmed (e.g.,
ENTRY/EXIT, PERIMETER, INTERIOR, etc.) and the procedure for programming the receivers.
These receivers should not be installed in an area subject to environmental extremes of below freezing (such as an unheated warehouse) or extremely high temperatures (such as an
attic).
INSTALLATION
With some controls, a receiver may be mounted directly inside the control's cabinet (receiver circuit board only, without its plastic housing) instead of remotely (in its own housing). In both
cases, avoid mounting the receiver antennas against a metal surface.
NOTE: You may only mount the 5881ENHC its own plastic housing. If you attempt to mount the 5881ENHC in the control's cabinet, the receiver constantly reports a tamper condition.
Mounting
1. Remove the receiver's cover by inserting a screwdriver blade in the slot at the center of the cover's lower edge.
2. If the receiver is to be mounted within the control's cabinet (refer to Figure 2):
a. Remove the receiver's circuit board from its base by bending back the two flexible plastic tabs that hold the
board's lower edge.
b. In the control's cabinet, unfasten and move the control circuit board downward (if already installed).
c. Hang two mounting clips (provided with the receiver) on the raised cabinet tabs, as shown in Detail B of
Figure 2.
d. Insert the top of the receiver board between the rows of slots at the top of the cabinet, as shown in Detail A.
e. Position the base of the receiver board onto the mounting clips and secure to the cabinet using the screws
supplied. See Detail B.
f. Hang two mounting clips (supplied with control board), on the raised cabinet tabs see Detail C in Figure 2.
g. Insert the top of the control board into the slots of the mounting clips secured in step e above.
h. Position the lower end of the control board into place on the mounting clips and secure both to the cabinet
with the two supplied screws.
i.
Insert both grounding lugs (supplied with the receiver) through the top of the cabinet into the left-hand
terminals of the antenna blocks (located on the upper edge of the receiver board), and secure them to the
cabinet with the screws provided, as shown in Detail D.
j.
Insert the receiver's antennas through the top of the cabinet, into the blocks' right-hand terminals, and
tighten the screws.
k. Affix the receiver's Summary of Connections label to the inside of the control's cabinet door.
l.
Discard the receiver's unused plastic cover and base.
3. If the receiver is to be located remotely from the control in its own plastic enclosure (not in a cabinet) you will
not need the circuit board mounting clips, grounding lugs and screws included with the receiver.
a. If concealed wiring is to be used, route it through the rectangular opening at the rear of the base before
mounting. For surface wiring entry, a thin breakaway area is provided along the base's right edge.
b. Mount the receiver in the selected location. For greatest security, use all four mounting holes (two key slot
holes and two round holes) provided in the plastic base.
c. If installing a 5881ENHC, install a flat-head screw (supplied) in the case tamper tab as shown in Figure 3.
When the receiver is pried from the wall, the tamper tab will break off and remain on the wall. This will
activate a tamper switch in the receiver and cause generation of a tamper signal. Note that this signal will
also be generated when the receiver's front cover is removed.
d. Affix the receiver's Summary of Connections label to the inside of the housing cover.
4. Setting the DIP switches (All Receivers):
a. Set the receiver's DIP switch (#2 through #4) to identify the receiver's address (refer to the DIP switch chart
in the Summary of Connections Diagram below).
b. Verify that DIP switch #1 is in the OFF position.
c. Set DIP switch #5 according to the following chart.
DIP SWITCH #5
For . . .
Commercial Fire Applications
Non-commercial Fire Applications
NOTES:
If multiple receivers are used on one control, DIP switch #5 must be set to the same position on all
receivers.
DIP switch #5 reduces sensitivity during supervision message reception. For commercial fire applications,
DIP switch #5 must be in the ON position.
5. Insert the wiring plug (with 4 flying leads) into the mating socket on the receiver (see Summary of Connections
Diagram below for socket location). Connect the 4 wires to the control's corresponding keypad terminals (see
"Interface Wiring" in the SPECIFICATIONS section below).
6. Install the antennas in the right-hand terminals of the two terminal blocks at the upper edge of the circuit board,
one into each block's right-hand terminal, and tighten the screws to secure them.
Caution: Avoid mounting the receiver antennas against a metal surface.
7. Replace the unit's front cover using the supplied screw to secure it.
8. Proceed with any programming of the control that may be necessary for RF operation, and the installation of the
system's wireless transmitters, as described in the control's installation and setup guide and the transmitter's
installation instructions.
NOTES:
• The receiver can support up to 16 high security (encrypted) wireless transmitters (keys). The total quantity of
wireless keys (encrypted and unencrypted) that can be used is determined by the control panel.
• Wireless key buttons must be enrolled to zones in the control panel via zone programming first. If the wireless
key is to be used for arming and disarming the VISTA-40 and up, a user number must then be assigned to
the wireless key via user programming. If it is not done in this order, you will be unable to respond
successfully to the RF button zone number prompt in user programming.
• If more than one receiver is being used and you are using encrypted wireless keys, we recommend that you
(a) enter the GO/NO GO mode, (b) disconnect one receiver, (c) enroll all encrypted keys into the connected
receiver, (d) reconnect the disconnected receiver, (e) exit the GO/NO GO mode, and then (f) repeat (a)
through (e) for the receiver that was disconnected.
• The RED LED located on the receiver's circuit board should be used as an indicator of strong local radio
frequency interference. If this LED is continuously illuminated, the receiver should be relocated.
After a successful enrollment of an encrypted key, the GREEN LED blinks the number of spaces that are
free for additional encrypted key enrollment.
9. Replace the receiver's cover.
Set to . . .
ON
OFF
CONTROL
PANEL*
ECP
ISOLATOR
KEYPAD
TERMINALS
ON
CONTROL
BOARD
TO FIRE DEVICES
*CONTROL MUST BE CAPABLE OF
SUPPORTING A 5800 RF SYSTEM
Figure 1. 5881EN Receiver System Overview
Mounting UL Commercial Fire Applications
NOTE: For UL-864 Fire installations, ECP Isolator (PN ECP-ISO) is required.
• Each receiver supports the number of zones shown below.
5881ENL up to 8 zones
5881ENM up to 16 zones
5881ENH *see below
5881ENHC *see below
* The number of zones that the 5881ENH receiver can support depends on the
control with which it is used. See the control panel's instructions for specific details.
Supporting
Remove Screw
And Pry Open
Installing the Receiver Board in Control's Cabinet
Mounting
Screws
4 (Typ)
Screw
Figure 4: 5881EN Remote Mounting
5800 SERIES
TO
WIRELESS
BURGLARY
TRANSMITTERS
DEVICES
5881ENHC
RECEIVER
Holes For Antennas
And Grounding Lugs
Board
Circuit
Slots
Board
DETAIL A
Side View
Of Board
Supporting
DETAIL B
Side View
Of Mounting
Of Mounting
Locking Tab
Figure 2.
SCREW
5881ENHC-001-V0
Figure 3: Tamper Protection
ECP
Connection
Front Tamper
(Rear Tamper)
Locking
Tab
Cabinet
Slots
Clip
DETAIL C
Side View
Clip

Advertisement

loading

Summary of Contents for Honeywell ADEMCO 5881EN Series

  • Page 1 ADEMCO 5881EN Series RF Receiver – Installation Instructions INTRODUCTION The 5881EN RF Receiver is designed for use with control panels that support an RF receiver connection via the keypad terminals. The 5881EN Series Receivers recognize alarm, status, and keypad control messages from •...
  • Page 2 For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa. Patents Warranty MyWebTech For patent information, see www.honeywell.com/patents 2 Corporate Center Drive, Suite 100 ÊN7635-3V5GŠ P.O. Box 9040, Melville, NY 11747 © 2004 Honeywell International Inc. www.honeywell.com/security N7635-3V5 1/16 Rev. A...