RIDGID SeekTech SR-20 Operator's Manual page 13

Pipe, cable and sonde locator
Hide thumbs Also See for SeekTech SR-20:
Table of Contents

Advertisement

Available languages

Available languages

Figure 13 – Line Trace Frequency Selected with
Frequency Key
(This screen will flash briefly when a new frequency is
chosen.)
Activating Frequencies
Each frequency is activated by choosing it from a list in the
Main Menu (See Figure 15). Frequencies are grouped by
category:
Sonde
Active Line Trace
Passive Line Trace
Radio
1. Push the Menu Key:
Figure 14 – Menu Key
The Main Menu is then activated:
Figure 15 – Main Menu
2. Using the up and down arrows, highlight the fre-
quency desired. In Figure 16, below, the operator is
activating a 128 Hz frequency.
Figure 16 – Highlighting a Desired Frequency (128 Hz)
3. Press the Select Key
for each frequency intended for use.
Figure 17 – Select Key
Figure 18 – Desired Frequency Checked
4. Frequencies that have been selected for use will
show a check in the box next to them.
5. Press the Menu Key
and exit.
Ridge Tool Company
SeekTech SR-20
(Figure 17) to check the box
again to accept the choices
11