Mounting the DC Power Supply

Warning
Read the wall-mounting instructions carefully before beginning installation. Failure to use the
correct hardware or to follow the correct procedures could result in a hazardous situation to people
and damage to the system. Statement 378
The Cisco 800M ISR DC power supply may be mounted to a wall using four #6 pan- or round-head wood
screws for the mounting holes on the supply.
Each mounting screw must go into a wall stud (wood) or a wall anchor of the appropriate type for the
Caution
wall. Screws into drywall is not sufficient to support the DC power supply.
If the screws are not properly anchored, the strain of the DC supply cables could pull the router from the
Caution
wall.
To mount the DC power supply to the wall, follow these instructions:
Step 1
Install the four screws into the mounting holes on the DC power supply as shown in
being secured to the wall studs or wall anchors.
Cisco 800M Series Integrated Services Router Hardware Installation Guide
2-14
1
End of tabs
For attaching to a wall stud, the power supply requires #6 wood screws (round- or pan-head). The
screws must be long enough to penetrate and tap at least 0.75 inches (19.1 mm) into the supporting
wood or metal wall stud.
For hollow-wall mounting, the power supply requires the use of appropriate-sized wall anchors that
work with the drywall thickness the unit is to be installed in. Use hollow-wall anchors that support
using #6 screws and use #6 pan- or round-head screws to secure the power supply to the wall. Each
wall anchor should be rated for at least 30 lbs.