Activate A Dc Power Supply Module; Port Connection Guidelines - Cisco N540-FH-CSR-SYS Install Manual

Hide thumbs Also See for N540-FH-CSR-SYS:
Table of Contents

Advertisement

Activate a DC Power Supply Module

Figure 16: Attach the DC Power Supply Wires
Activate a DC Power Supply Module
Perform the following procedure to activate a DC power supply:
Step 1
Remove the tape from the circuit-breaker router handle, and restore power by moving the circuit-breaker router handle
to the On (|) position.
Step 2
Verify the power supply operation by checking whether the respective power supply front panel LED (PS0 or PS1) is
green.
Step 3
If the LEDs indicate any issues with power problem, see Troubleshooting.
Step 4
If you are also connecting a redundant DC power supply, repeat these steps for the second power source.
If you are connecting a redundant DC power supply, ensure that each power supply is connected to a separate
Note
power source in order to prevent power loss in the event of a power failure.

Port Connection Guidelines

Depending on the chassis and installed line cards, you can use Quad Small Form-Factor Pluggable Plus
(QSFP+), QSFP28, SFP, SFP+, and RJ-45 connectors to connect the ports on the line cards to other network
devices.
To prevent damage to the fiber-optic cables, we recommend that you keep the transceivers disconnected from
their fiber-optic cables when installing the transceiver in the line card. Before removing a transceiver from
the router, remove the cable from the transceiver.
To maximize the effectiveness and life of your transceivers and optical cables, do the following:
Install the Device
12