Cisco Catalyst 2924M XL Using Manual
Cisco Catalyst 2924M XL Using Manual

Cisco Catalyst 2924M XL Using Manual

Dc ethernet switch
Hide thumbs Also See for Catalyst 2924M XL:

Advertisement

Quick Links

Using the Catalyst 2924M XL DC
Ethernet Switch
April 21, 2000
This document describes the Catalyst 2924M XL DC Ethernet switch (hereafter
referred to as the switch) and provides the instructions for rack-mounting it and
connecting it to a DC-input power source.
Note
This document uses the term switch to refer to the
Catalyst 2924M XL DC switch. In this document, the term switch
does not refer to a telco device.
Contents
Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Copyright © 2000. Cisco Systems, Inc. All rights reserved.
"Conventions" section on page 2
"Introduction" section on page 6
"DC-Power Specifications and Agency Approvals" section on page 7
"Warnings" section on page 8
"Preparing for Installation" section on page 9

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 2924M XL

  • Page 1 “DC-Power Specifications and Agency Approvals” section on page 7 • • “Warnings” section on page 8 “Preparing for Installation” section on page 9 • Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA Copyright © 2000. Cisco Systems, Inc. All rights reserved.
  • Page 2 Note references to materials not contained in this manual. Means reader be careful. In this situation, you might do something Caution that could result in equipment damage or loss of data. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 3 Tässä julkaisussa esiintyvien varoitusten käännökset löydät laitteen mukana olevasta Regulatory Compliance and Safety Information -kirjasesta (määräysten noudattaminen ja tietoa turvallisuudesta). Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 4 å unngå ulykker. Hvis du vil se oversettelser av de advarslene som finnes i denne publikasjonen, kan du se i dokumentet Regulatory Compliance and Safety Information (Overholdelse av forskrifter og sikkerhetsinformasjon) som ble levert med denne enheten. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 5 Se förklaringar av de varningar som förkommer i denna publikation i dokumentet Regulatory Compliance and Safety Information (Efterrättelse av föreskrifter och säkerhetsinformation), vilket medföljer denna anordning. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 6 Introduction Introduction The Catalyst 2924M XL DC switch is equipped with an on-board direct-current (DC) power converter. The DC-power converter has dual feeds (A and B) that are diode OR’d into a single power block. The front panel of the switch provides 24 10/100 ports, 2 high-speed expansion slots, a set of LEDs, and a Mode button.
  • Page 7 DC-Power Specifications and Agency Approvals The switch is for use in DC operating environments and has the following power-source specifications and agency approvals: Table 1 Power Specifications for the Catalyst 2924M XL DC Switch Description Design Specification Power 100W, –36 to –72 VDC...
  • Page 8 Warning insulation between the primary AC power and the 48-VDC output. Warning The Catalyst 2924M XL DC switch is intended for Local Area Network (LAN) connections only. This unit is not certified for use in Public Telephone Networks. The Catalyst 2924M XL DC switch contains no field-replaceable Warning units (FRUs).
  • Page 9: Preparing For Installation

    CT-700, CT-720, CT-920, CT-930, CT-920CH, or CT-940CH • 6-gauge copper ground wire (insulated or noninsulated) Four leads of 12- or 14-gauge copper wire • • Wire-stripping tool(s) for stripping both 6- and 12- or 14-gauge wires Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 10: Rack-Mounting The Switch

    The rack-mounting brackets supplied with the switch can be attached to a 19-, 23-, or 24-inch rack. 19" rack 24" rack 23" rack ount point mount point mount point 19" rack 24" rack 23" rack ount point mount point mount point Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 11 Use two of the supplied Phillips machine screws to securely attach each bracket to the rack. Phillips machine screws INPUT : 36 - 72 CURR ENT: 4-2A + – + – Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 12: Grounding The Switch

    Phillips head to remove the two number-10-16 ground-lug screws and the ground lug from the rear panel of the switch. INPUT: 36 - 72 CURREN T: 4-2A + – + – REFER TO MANUAL BEFORE CONNEC TING POWER CONSOL E Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 13 Slide the open end of the ground lug over the exposed area of the 6-gauge wire. Step 5 Using a Panduit crimping tool, crimp the ground lug to the 6-gauge wire. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 14 Using a ratcheting torque screwdriver, torque each ground-lug screw to 15 1bf-in. (or 240 ounce-force inches [240 ozf-in.]). INPUT: 36 - 72 CURREN T: 4-2A + – + – REFER TO MANUAL BEFORE CONNEC TING POWER CONSOL E Torque to 15 lbf-in. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 15: Wiring The Dc-Input Power Source

    Follow these steps for wiring the switch to a DC-input power source. Locate this terminal block plug. It is shipped already inserted in the DC power Step 1 connector on the switch back panel. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 16 DC-input power source to 0.27 inch ± 0.05 inch. Do not strip more than 0.29 inches of insulation from the wire. Stripping more than the recommended amount of wire can leave exposed wire from the terminal block plug after installation. 0.27" ± 0.05" Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 17 An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug. Return Feed A Negative Return Feed B Negative Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 18 (above the installed wire lead) to 4.5 1bf-in. (72 ozf-in.). Do not overtorque the terminal-block captive screws. The Caution recommended maximum torque is 4.5 lbf-in. (72 ozf-in.). Torque to 4.5 lbf-in. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 19 Repeat steps 4 and 5 for the remaining three DC-input power source wires. The following figure shows the completed wiring of a terminal block plug. Return Feed A Negative Return Feed B Negative Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 20 BEFORE CONNEC TING POWER CONSOL E Tie wrap Step 8 Remove the tape from the circuit-breaker switch handle, and restore power by moving the circuit breaker handle to the on position. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 21: Translated Safety Warnings

    48 volts likestrømsutgangen. Aviso O sistema habitual de corrente de 48 volts deverá fornecer isolamento reforçado entre a corrente alternada (AC) principal e a saída de 48 VDC (tensão em corrente contínua). Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 22 48 V likström. LAN Connections Only Warning The Catalyst 2924M XL DC switch is intended for Local Area Warning Network (LAN) connections only. This unit is not certified for use in Public Telephone Networks.
  • Page 23 Aviso El conmutador Catalyst 2924M XL DC ha sido diseñado para su uso exclusivo con conexiones WAN (Redes de área amplia). Esta unidad no ha recibido certificación para su uso en redes telefónicas públicas.
  • Page 24 Ciscon myyntiedustajalta. Attention Le Catalyst 2924M XL DC ne dispose pas d'unités remplaçables sur site (FRU). Il est recommandé de ne pas ouvrir le châssis ni de retirer ou remplacer des composants. Pour plus de détails sur la maintenance de cette unité, contactez votre revendeur ou votre...
  • Page 25 Cisco. Varning! Catalyst 2924M XL DC innehåller inte några enheter som kan bytas ut på fältet. Öppna inte chassit och försök inte heller att ta bort eller byta ut några delar. Kontakta återförsäljaren eller representanten för Cisco om du behöver information om service av...
  • Page 26: Installation Warning

    Leia as instruções de instalação antes de ligar o sistema à sua fonte de energia. ¡Advertencia! Ver las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Varning! Läs installationsanvisningarna innan du kopplar systemet till dess strömförsörjningsenhet. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 27 Conecte o equipamento a uma única fonte de segurança de baixa tensão (SELV). ¡Advertencia! Conecte el equipo a una única fuente de voltaje extra-bajo (SELV, extra-low voltage source). Anslut utrustningen till en enstaka, SELV (skyddskrets för mycket Varning! låg spänning) strömförsörjningskälla. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 28: Restricted Access Warning

    O equipamento é para ser instalado numa área de acesso restrito. ¡Advertencia! El equipo debe instalarse en una zona de acceso restringido. Varning! Utrustningen måste installeras på plats med åtkomst endast för behörig personal. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 29 Os cabos “Ethernet” deverão estar armados quando usados em ambiente de escritório central. ¡Advertencia! Los cables Ethernet deben estar protegidos cuando se usen dentro de una oficina central. Varning! Ethernetkablar måste vara avskärmade vid användning i central kontorsmiljö. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 30: Grounded Equipment Warning

    Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo. Advarsel Dette utstyret skal jordes. Forviss deg om vertsterminalen er jordet ved normalt bruk. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 31 Este equipo debe conectarse a tierra. Asegurarse de que el equipo principal esté conectado a tierra durante el uso normal. Varning! Denna utrustning är avsedd att jordas. Se till att värdenheten är jordad vid normal användning. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 32: Ground Connection Warning

    última a ser desligada. ¡Advertencia! Al instalar el equipo, conectar la tierra la primera y desconectarla la última. Varning! Vid installation av enheten måste jordledningen alltid anslutas först och kopplas bort sist. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 33: Qualified Personnel Warning

    ¡Atención! Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado. Varning Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 34: Dc Power Disconnection Warning

    Strom abgestellt ist, machen Sie auf der Schalttafel den Unterbrecher für die Gleichstromschaltung ausfindig, stellen Sie den Unterbrecher auf AUS, und kleben Sie den Schaltergriff des Unterbrechers mit Klebeband in der AUS-Stellung fest. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 35 Innan du utför någon av följande procedurer måste du kontrollera att strömförsörjningen till likströmskretsen är bruten. Kontrollera att all strömförsörjning är BRUTEN genom att slå AV det överspänningsskydd som skyddar likströmskretsen och tejpa fast överspänningsskyddets omkopplare i FRÅN-läget. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 36 Assicuratevi che i cavi in uscita dall'alimentatore DC-input non presentino punti scoperti. Advarsel En avdekket ledning fra en likestrømskilde kan lede farlig elektrisitet. Kontroller at ingen avdekkede deler av ledningen til likestrømskilden stikker ut av terminalens koblingsblokk. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 37 DC de entrada sale del enchufe del bloque de terminal. Varning! En blottad trådledning från en likströmsförsörjningsenhet kan utgöra en ledare för skadliga elektricitetsnivåer. Se till att inte någon blottad ledningsdel från likströmsförsörjningsenheten sticker ut från stiftplinten. Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...
  • Page 38: Related Documentation

    Use the Catalyst 2900 Series XL Installation Guide with this document and this product. Obtaining Documentation World Wide Web You can access the most current Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com. Documentation CD-ROM Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product.
  • Page 39: Obtaining Technical Assistance

    Obtaining Technical Assistance Obtaining Technical Assistance Cisco provides Cisco Connection Online (CCO) as a starting point for all technical assistance. Warranty or maintenance contract customers can use the Technical Assistance Center. All customers can submit technical feedback on Cisco documentation using the web, e-mail, a self-addressed stamped response card included in many printed docs, or by sending mail to Cisco.
  • Page 40: Technical Assistance Center

    Documentation Feedback If you are reading Cisco product documentation on the World Wide Web, you can submit technical comments electronically. Click Feedback in the toolbar and select Documentation. After you complete the form, click Submit to send it to Cisco.
  • Page 41 NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any of its resellers.
  • Page 42 Obtaining Technical Assistance Using the Catalyst 2924M XL DC Ethernet Switch 78-10499-01...

Table of Contents