Wireless Audio keypad with integrated tag reader and siren
Introduction
The LKPES8M-EN is designed to control the
DOMONIAL 7/7G panel's series. The primary
function of this fully wireless keypad is to arm and
disarm the system. This can be done either by
entering a code on the numeric keypad or by using
the integrated proximity tag reader. The LKPES8M-
EN also features an integrated siren and can be used as a remote audio
verification device between the monitoring station and the protected area.
Mounting
The keypad must be installed on its mounting bracket and is not meant to be
used outside its bracket. This bracket must be fixed on a wall and easily
accessible for the arming and disarming of the system.
Mounting steps:
1) Separate the bracket from the keypad (see drawing 4 page 1)
2) Fix the bracket on the wall using screws (see drawing 4 page 1)
3) Insert the battery keeping the polarities.
4) Put the keypad back in its bracket.
5) Depending on the regulation in force in the country, the keypad could be
secured in its bracket with the supplied screw.
Registering
The registering is the procedure associating the keypad to the panel. This
operation requires a programming tool. The complete procedure
is described in the alarm central unit installation notice or in the programming
tool manual.
Up to 2 audio keypads can be used per installation and up to 3 keypads if the
audio functionality is disabled.
1) Connect the programming tool and start programming.
2) Go to the « Register » menu and put the panel into registration mode.
3) To register the keypad, insert the batteries or remove the keypad from its
mounting bracket to trigger a tamper fault or trigger an alert by pressing
simultaneously
and
keys (see page
configuration of the panel, the keypad and panel will beep to confirm the
registration.
4) Configure the keypad in the programming tool:
- Set label of the device
- Choose alert mode (1: silent, 2: beep or 3: siren)
- Choose associated set (Total, Annex or Total + Annex)
5) Get out of programming mode
IMPORTANT: The keypad must always be programmed in its final
location with a minimum radio level of 3 units on a scale of 10
Power and Maintenance
The keypad signals a battery failure at the control panel when the
battery needs to be replaced. LED2 will light on to signal locally to the end
user the battery default (see drawing 1 page 1). The keypad will continue to
operate for up to one month after this event. Replace battery with CR123A 3V
Lithium battery type only.
To replace the battery follow the procedure described bellow:
1) Remove the keypad from its mounting bracket.
2) A tamper alarm is sent to the panel. There is a 120-seconds delay
(depending on panel configuration) before transmitting the specific tamper
message to the monitoring station. If tamper is restored before the end of
the delay, no transmission will occur. (The tamper delay is only when the
system is disarmed. Tamper is immediately transmitted if the panel is
armed)
3) Remove the batteries and replace them with new batteries from the same
type
4) Put the keypad back on the bracket
To clean the keypad, use a dry cloth only (no detergent).
Programming the Keypad (Installer mode)
The keypad features 2 programming modes which allow the installer and end
user to control the keypad functionalities.
The procedure bellow explains the procedure to enter the installer
programming mode. For details on the end user's programming mode please
1).
Depending on the
- 2 -
refer to the user's manual.
To enter installer's programming mode:
1) Press simultaneously keys
and
and release them.

A double beep is played and all LEDs light up.
2) Enter installer's code

All LEDs start flashing and a long beep is played
To exit installer's programming mode and save your
changes:
1) Press
to exit programming and save your
changes

All LEDs stop flashing and a double beep is played.
Note: The system will automatically exit programming mode after
20 seconds if no keys are pressed during this period. If this occurs, you
must repeat all the steps necessary for the function you are using.
In programming mode, it is possible to:
Set arming with identification:
1. Press
to select function
2. Press
to activate arming with identification (code or TAG)
Set quick arming:
1. Press
button to select function
2. Press
to activate quick arming
Associate a TAG to a user:
1. Press a numeric key to select user's number [ 0...9 ]
2. Present the TAG
Note: The keypad will automatically get out of programming mode if the
TAG is already registered. If the user already has a TAG, it is replaced by
the new one
.
Change a user's code:
1. Press a numeric key to select user's number [ 0...9 ]
2. Enter new user's code
3. Re-enter new user's code
Disable a user's code (disable the code for a user and keep
the TAG only):
1. Press a numeric key to select user's number [ 0...9 ]
2. Enter 0000 (or 000000 if 6 digits)
3. Re-Enter 0000 (or 000000 if 6 digits)
4. Press
Disable a user:
1. Press a numeric key to select user's number [ 0...9 ]
2. Press
to disable the user
Enable a user:
1. Press "0 to 9" button to select user's number
2. Press
to enable the user
Note: it is possible to set a code and/or a tag to each user. The keypad
can have up to 10 users. The keypad can also be programmed to manage
4-digit or 6-digit codes (using programming tool).
Audio Configuration
The wireless audio verification functionality is configured from the
programming tool. Please refer to the programming tool documentation to
obtain further details
more than 3 seconds