Led systems power supply, 12 volt

Advertisement

Quick Links

GE
Lighting Solutions
Tetra
LED Systems Power Supply
®
(GEPS12-60 & GEPS12-60U)

Power Supply Features

• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX
and Tetra PowerStrip LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• Damp location rated
• IP66 rated: separate enclosure required

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE:
• Use only Tetra
supply wire to make connection from Tetra
®
supply to Tetra
LED strip.
®
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82mm
• Follow all local codes.

Power Supply Installation

Black (line)
AC line
Connect the AC line to the black
1
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
18-10AWG (0.82-5.26 mm
wire connectors.
imagination at work
WARNING/AVERTISSEMENT
)
2
Input
wires
Red (+)
White (neutral)
Connect the supply wire that is
2
attached to the Tetra LED System to
the red (+) and black (-) output wires
) or
of the power supply as outlined
2
) twist-on
in the "Electrical Connections"
2
section of your LED system's
Installation Instructions.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation
électrique Tetra
RISQUES D'INCENDIE
power
®
• N'utilisez que le fil d'approvisionnement Tetra® pour faire la
connexion entre l'alimentation Tetra
• N'utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82mm
• Respectez tous les codes locaux.
To Tetra LED System
Black (-)
Output
wires

Installation Guide

.
®
et la bande DEL Tetra
®
).
2
NOTE: Power Supply Loads
Exceeding maximum load will cause the
power supply to shut down. Once the
excess load is removed, cycle the input
power to restart the power supply.
Specific load information for the supported
LED systems can be found in the "Power
Supply Specifications" section on the next
page.
NOTE: For CSA approval, a disconnect/
toggle switch of appropriate rating needs
to be placed within 29 feet (8.84 meters)
of primary side of the power supply. The
minimum rating of the switch must be
either 120 or 220 Volts AC. The switch
must also support twice the amount of
input current.
12
Volt
.
®

Advertisement

loading

Summary of Contents for GE Tetra GEPS12-60

  • Page 1: Installation Guide

    Installation Guide Lighting Solutions Volt Tetra LED Systems Power Supply ® (GEPS12-60 & GEPS12-60U) Power Supply Features • Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX and Tetra PowerStrip LED lighting systems • Class 2 wiring per NEC Article 725 (SELV) •...
  • Page 2: Power Supply Specifications

    1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.