Download Print this page
GE Tetra GEPS24-100U-GLX Installation Manual

GE Tetra GEPS24-100U-GLX Installation Manual

Led systems power supply

Advertisement

Quick Links

Tetra
®
LED Systems Power Supply
GEPS24-100U-GLX

Power Supply Features

• Supports Tetra PowerStrip SS, Tetra PowerStrip DS, Tetra miniStrip DS,
Tetra Edgestrip, Tetra Contour, Tetra Contour LS, Tetra miniMAX,
Tetra MS, Tetra MAX, Tetra PowerMAX, Tetra PowerMAX HO and Tetra Stick
LED lighting systems
• UL: Class 2 wiring per NEC Article 725, dry and damp location rated
• IEC: SELV, CE: IP54 rated, must be protected from direct exposure to the weather

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Disconnect power at fuse box or circuit breaker before servicing
or installing product.
• Properly ground Tetra
power supply.
®
• AC input connections shall be suitably enclosed. The power
supply shall be enclosed or made inaccessible to users during
normal use.
RISK OF FIRE
• Minimum power supply spacing to other power supply or other
heat producing component shall be at least 4" (101.6 mm) from
side to side and 1" (25.4mm) from end to end.
• Use only approved wire for input/output connection. Minimum
size 18 AWG (0.82 mm
).
2
• Follow all local codes.
RISK OF INJURY
• While performing installations described, gloves, safety glasses
or goggles should be worn.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
Electrical Requirements
• Limited to use in dry and damp locations.
• The suitability of rain enclosure shall be determined if
intended for wet location.
• The grounding and bonding of the LED Driver shall be
done in accordance with National Electric Code (NEC)
Article 600.
• Follow all National Electric Codes (NEC) and local codes.
WARNING/AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au disjoncteur avant
l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation électrique Tetra
RISQUES D'INCENDIE
• N'utilisez que des fils approuvés pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
CAUTION/ATTENTION
RISQUE DE BLESSURE
• Lors de l'exécution des installations décrites, des gants, des lunettes de
sécurité ou des lunettes de protection doivent être portées.
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own
expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR
de la classe [A] est conforme à la NMB-005 du Canada.
1
Installation Guide
).
2
24
Volt
.
®

Advertisement

loading

Summary of Contents for GE Tetra GEPS24-100U-GLX

  • Page 1: Power Supply Features

    Tetra ® LED Systems Power Supply Installation Guide GEPS24-100U-GLX Volt Power Supply Features • Supports Tetra PowerStrip SS, Tetra PowerStrip DS, Tetra miniStrip DS, Tetra Edgestrip, Tetra Contour, Tetra Contour LS, Tetra miniMAX, Tetra MS, Tetra MAX, Tetra PowerMAX, Tetra PowerMAX HO and Tetra Stick LED lighting systems •...
  • Page 2: Power Supply Installation

    Power Supply Installation To Tetra LED System Input wires Black (-) Red (+) Black (line) White (neutral) Output wires AC line Mount the power supply. Mounting Connect the AC line to the black Connect the supply wire that is the power supply base directly to (line) and white (neutral) input attached to the Tetra LED System to a thermally conductive installation...
  • Page 3: Power Supply Specifications

    Power Supply Specifications Performance Data Typical Input Voltage (VAC) 120-277 Input Frequency (Hz) 50/60 Input Current (A) 0.35 Output Voltage (VDC) 24.5 25.2 Output Current (ADC) Output Power (W) Environmental Operating Temperature Range -40°C +25°C +60°C* Environmental Humidity (non-condensing) Environmental Storage Temperature Range -40°C +85°C Dimensions...
  • Page 4 Chart continued Remote Mounting Distance Supports Maximum Load 18 AWG/ 16 AWG/ 14 AWG/ 12 AWG/ Tetra Products SKUs Rated Power per Power Supply 0.82 mm 1.31 mm 2.08 mm 3.31 mm Tetra Contour LS GEXNLRD-1 1.30W/ 69 ft. (21m) 20 ft.(6.1 m) 30 ft.(9.1 m) 50 ft.(15.2 m)
  • Page 5 Chart continued Remote Mounting Distance Supports Maximum Load 18 AWG/ 16 AWG/ 14 AWG/ 12 AWG/ Tetra Products SKUs Rated Power per Power Supply 0.82 mm 1.31 mm 2.08 mm 3.31 mm Tetra Stick GETSPMSS01871A1 / GETSPMSS01871B1 1.7 W/Stick 47 Sticks 20 ft.(6.1 m) 25 ft.(7.6 m) 35 ft.(10.6 m) 40 ft.(12.1 m) GETSPMSS02471A1 / GETSPMSS02471B1 2.5 W/Stick...
  • Page 6: Troubleshooting

    All trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. Current, powered by GE is a business of the General Electric Company. © 2018 GE.