Timer
The access rights can be distributed over two time zones via the input "Timer":
brown + black open
brown + black closed
The timer must have a potential-free contact.
Printer
The access control bookings (see example) as well as a system data printout can be listed.
The printer must have the following features:
-RS 232 C serial interface
-600 Baud
-8 data bits
-EVEN parity
-1 Stop bit
The line RxD of the printer (see printer manual) is connected with the red/blue line of the ACC 50.
The following information is provided::
-Card contents of the read-in ID card
-Door status: valid
invalid
Example:
(= authorized access, door is released)
(= no authorized access, door remains locked)
0000060808010504
0000060808010505
0000060808010506
0000060808010508
= time zone "A"
= time zone "B"
invalid
invalid
valid
valid