Available languages

6
1.
Application
For monitoring entrances to buildings that are not opened but that can be entered by climbing in
(not by reaching through).
Examples: Skylights, openings for ventilation equipment, emergency exits, display cabinets, etc.
The contact can also be used to "trip" intruders.
Due to the position of the internal magnetic contact, the trip wire contact reacts when the wire is
both pulled and broken.
2.
Setup
Connection points
3.
Function
In the normal operating state, the magnet is
positioned in the middle and the magnetic contact is
therefore closed.
When pulled or broken, the magnet moves away
from its position in the middle and the contact
opens.
4.
Connection
Stop
Breakage
Magnet
1
2
3
4
Cover contact
Position of magnet in normal operating state
Alarm
detector group
Tamper detector
group
Mounting and Connection Instructions - Trip Wire Contact
Stop
Pull
1
Magnetic contact
2
3
Cover contact
4
Eyelet for securing wire
Magnet
Breakage
Magnetic contact
Pull