  • Page 1 MDS P-60/P-60 HL Packaged Radio System Including Reference Material for Legacy MDS P-50 Packaged Models 05-2818A01, REV. C AUGUST 2009 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 2 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 3: Table Of Contents

    Board (P/N 03-2110A01) ..............19 2.6 Data Connections—Digital Interface/ Utility Board (P/N 03-2472Axx) ............23 2.7 Final MDS P-60 Installation Tasks ..........25 3.0 MDS P-50 installation ..............26 3.1 Unpacking and Inspection .............. 26 3.2 Installation Considerations ............. 26 3.3 Mounting the Enclosure ..............26...
  • Page 4 GE MDS Quality Policy Statement We, the employees of GE MDS, are committed to achieving total cus- tomer satisfaction in everything we do. Total Customer Satisfaction in: •...
  • Page 5 Customer Service Team using the information at the back of this guide. In addition, manual updates can often be found on the GE MDS Web site at www.gemds.com...
  • Page 6 MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 7: Introduction

    Tells how the manual is organized and describes the features and differ- ences of the various packaged systems. You are in this section now. • Chapter 2—MDS P-60 Installation Provides the steps to mount the MDS P-60 and make the cable connec- tions. • Chapter 3—MDS P-50 Installation Provides the steps to mount the MDS P-50 and make the cable connec- tions.
  • Page 8: Equipment Description

    1.2 Equipment Description GE MDS packaged systems include a radio transceiver, power supply (with battery backup for AC-powered models) and Interface/Utility Board normally mounted inside a weather resistant, padlockable enclosure. The only connec- tions required are for primary power, antenna, and interface connection to the customer-supplied equipment.
  • Page 9 Refer to and comply with P-60 HL Packaged Radio - Hazardous Locations Installation Procedure (P000530) when installing these units. MDS P-60 Units Equipped with MDS iNET or TransNET Transceivers The P-60 can be equipped with various transceiver types. Depending on order requirements, the enclosure might contain one of MDS’...
  • Page 10 4.6 Ah for P-60 series, 5 Ah for P-50 series * Specifications are subject to change without notice. For radio specifications, refer to the associated transceiver instruction manual. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 11: Accessories

    Mounting kit for 19 inch rack; 15.75 inches high (mounts internal chassis) GE MDS publishes an Accessories Selection Guide which lists a complete array of additional items available for use with this product. Please contact your factory representative or visit www.GEmds.com...
  • Page 12: Mds P-60 Installation

    NOTE: outdoor installations. 2.3 Mounting the Enclosure There are two basic mounting arrangements for the MDS P-60—pole mount or wall mount. Methods for mounting the unit in both of these configurations follow. When planning the installation, refer to Figure 3 on Page 13, which shows the mounting dimensions of the MDS P-60 packaged system.
  • Page 13 Figure 3. MDS P-60 Mounting Dimensions Wall Mounting Instructions The steps below describe mounting of the MDS P-60 unit to a wall or other flat surface. Ordinary lag screws (with flat washers) can be used for mounting to a wooden surface. If it is to be mounted to a drywall, masonry or other non-wooden surface, suitable fasteners will be required that can support the weight of the unit.
  • Page 14 (SEE TEXT) 13.38" 34 cm TO PRIMARY COAXIAL CABLE POWER TO ANTENNA (CONDUIT) TO DATA EQUIPMENT (RTU) Figure 4. Typical Wall Mounted Installation (MDS P-60) MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 15 3/8" (9.5 mm). Longer screws will damage the enclosure. 2. With the help of an assistant, position the MDS P-60 enclosure on the pole at the desired mounting point. 3. Install the attaching hardware (with flat washers) in the center hole of the two brackets.
  • Page 16 The electrical installation procedures given in this section apply fully to rack mounted units. The physical mounting instructions, however, will differ, depending on the type of rack cabinet to be used. Contact GE MDS if addi- tional assistance is required.
  • Page 17: Mds P-60 Cable Connections

    ANTENNA CONNECTION Figure 7. MDS P-60 Cable Connection Points Primary Power—TB2 The power input terminations for the MDS P-60 are provided on the Inter- face/Utility Board connector TB2 via screw terminals (see Figure 8 on Page 19). Note that TB2 is used for input power regardless of whether the unit is configured for AC or DC operation.
  • Page 18 The MDS P-60 is normally wired by the factory for “floating” power connec- tions. However, either of th e primary power leads can be connected to TB2 Pin 2 (chassis ground), if desired, to configure the unit for positive or negative ground.
  • Page 19: Audio And Keyline Connections-Analog Interface/Utility Board (P/N 03-2110A01)

    Interface/Utility Board (P/N 03-2110A01) The Analog Interface/Utility Board serves as the connec tion point for all audio and keyline connections to the MDS P-60. Route the cabling to the Inter- face/Utility Board through the weathertight bushing on the bottom of the enclosure (also used for the antenna coaxial cable).
  • Page 20 25 volts, add a resistor in series with the connection to TB1 Pin 7 or TB1 Pin 8 to limit the keying current to 10 to 20 mA. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 21 L = AC Failure—Ground through a 1 K resistor Received Signal Strength Indicator (RSSI)—Pin 10 Same as transceiver’s RSSI output. It pr o vides a DC volt a ge proportional to the received signal strength. The range is approximately zero to five volts DC through a 10K current limiting resistor.
  • Page 22 Invisible place holder Figure 10. Keying Options, Analog Interface/Utility Board, P/N 03-2110A01 MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 23: Data Connections-Digital Interface/Utility Board (P/N 03-2472Axx)

    Utility Board (P/N 03-2472Axx) The Digital Interface/Utility Board serves as the connection point for all data connections to the MDS P-60. Route the cabling to the Interface/Utility Board through the weathertight bushing on the bottom of the enclosure (also used for the antenna coaxial cable).
  • Page 24 L = AC Failure—Ground through a 1 K resistor Received Signal Strength Indicator (RSSI)—Pin 11 Same as transceiver’s RSSI output. It pr o vides a DC volt a ge proportional to the received signal strength. The range is approximately zero to five volts DC through a 10K current limiting resistor.
  • Page 25: Final Mds P-60 Installation Tasks

    2.7 Final MDS P-60 Installation Tasks Perform the following steps to complete the installation of the MDS P-60 and prepare the unit for normal operating service: 1. Dress and secure all external cabling in conformance with applicable electrical codes. 2. Apply primary power to the unit and check for normal transceiver opera- tion.
  • Page 26: Mds P-50 Installation

    Specific items to check include: primary power voltage, transmit and receive frequencies, modem speed (if applicable), FM deviation, and transmitter RF power output. If there are discrepancies, contact GE MDS Customer Support at +1 (585) 242-9600 for assistance.
  • Page 27 Make sure the screws are tightened securely, but do not over-tighten. Figure 13 on Page 28 shows a typical wall mount installation. MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 28 3. Install the attaching hardware (with flat washers) in the center hole of the two brackets. 4. Tighten the fasteners securely, but do not over-tighten. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 29 (for use in excessively hot climates), a tower mounting bracket, and other arrangements to meet special needs. Con- tact GE MDS for more information. Rack Mount Alternative In addition to wall and pole mounting, the internal chassis of the packaged system can also be mounted in a standard 19 inch equipment rack for indoor installations.
  • Page 30 The electrical installation procedures given in this section apply fully to rack mounted units. The physical mounting instructions, however, will differ depending on the type of rack cabinet to be used. Contact GE MDS if addi- tional assistance is required.
  • Page 31: Mds P-50 Cable Connections

    Connector J3 is used for primary power input on AC-powered models. J3 Pins 1 and 3 are the AC line inputs. The AC Ground must be connected to J3 Pin 2 (chassis ground terminal). MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 32: Analog Interface/Utility Board Connections (P/N 03-1105A21)

    Board through the weathertight bushing on the bottom of the enclosure (also used for the antenna coaxial cable). Tighten the bushing after installing the interface cable. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 33 Connects to ground on the Interface/Utility Board. Received Signal Strength Indication (RSSI) Approximately 0 to 5 Vdc through a 10K resistor. Figure 17. Analog Interface/Utility Board Connections—MDS P-50 MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 34 Range is approximately zero to five volts DC through a 10K current limiting resistor. Refer to the transceiver manual for additional RSSI information. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 35 Figure 18. Keying Options—Analog Interface/Utility Board, P/N 03-1105A21 MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 36: Digital Interface/Utility Board Connections (P/N 03-1467A21)

    2. These lines are inputs: ETC, TXD and RTS. 3. These lines are outputs: TC, RC, RXD, CTS, DSR and DCD. 4. For asynchronous operation, make no connection to Pins 8, 9 or 10. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 37 Range is approximately zero to five volts DC through a 10K resistor. Refer to the trans- ceiver manual for additional RSSI information. MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 38: Final Mds P-50 Installation Tasks

    3. Close and latch the equipment cabinet. The cabinet latches may be pad- locked if desired. 4. If necessary, refine the antenna heading for maximum RSSI. (Refer to the transceiver manual for additional RSSI information.) MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 39: P-60/P-50 Operation

    A field upgrade kit (P/N 03-3077A11) is also available to add the Low Voltage Disconnect Assembly to older packaged radio units. Contact GE MDS for additional information. MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 40 Functional Description The Low Voltage Disconnect assembly is a small PC board mounted on the chassis plate of GE MDS packaged model radio systems. It prevents battery damage that may be caused by allowing a backup battery to drop below 10.2 volts while powering a transce iver, such as might occur during a lengthy power outage.
  • Page 41 14.10 Vdc (±0.1 V) must be present at the battery connector on the Interface/Utility Board (with the battery disconnected). This is the standard factory setting. MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 42: Interface/Utility Board Features And Indicators

    Interface/Utility indicator. (On Used to R10—RX audio Board with battery manually level operation.) key the R28—Order wire transceiver. CR10— deviation Transmitter keyed MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 43 Although many standard telephone handsets can be used for Order Wire service, GE MDS offers a unit specifically intended for use with its transceivers (P/N 12-1307A01). The Order Wire facility is not avail- able on units equipped with an MDS 9000 Series Transceiver.
  • Page 44 Figure 23. Order Wire Handset Connected to Packaged System (MDS P-60 shown; MDS P-50 similar) Connecting a Hand-Held Terminal A significant feature of GE MDS transceivers is the ability to accomplish many radio programming and diagnostic tasks through software commands issued from a Hand-Held Terminal (HHT). (See Figure 24 on Page 45.)
  • Page 45 (Kit P/N 03-1501A01) HHT Connection to an MDS P-60 On MDS P-60 models, an HHT can be plugged directly into the Inter- face/Utility Board (except for MDS x710 models, which require a diagnostics connection directly at the modular jack on the transceiver). Follow these steps to connect the terminal: 1.
  • Page 46 HHT or PC for diagnostic testing or link evaluation of an MDS 9300 Series spread spectrum transceiver. A standard RS-232/EIA-232 cable may be used for connection to a PC. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 47: Servicing Data

    Table 8 on page 48 contains a list of all fuses used in the packaged radio sys- tems. In the MDS P-60, all fuses are located on the Interface/Utility Board. In the MDS P-50, there are two fuses installed on the Interface/Utility Board and one fuse installed in the battery cabling (inline fuse).
  • Page 48: Backup Battery

    Backup Battery Replacement below for replacement instructions. Steps are also given later in this chapter for checking and adjusting the battery charging rate. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 49 Charging Adjustment Refer to Battery Charging Check—AC-Powered Units Only on page 65. (Sep- arate procedures are given for MDS P-50 and MDS P-60 Packaged systems.) MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 50: System Troubleshooting

    See also the troubleshooting instructions given in the associated transceiver manual. If troubles persist, technical assistance is available from GE MDS’ Customer Support by calling +1 (585) 242-9600. Please have the complete model number code of the packaged system ready when calling for assistance. Refer to the inside back cover of this manual for more information.
  • Page 51: List Of Replaceable Assemblies

    Therefore, not all of the parts listed will be used in every model. Please have the complete model number code for your packaged system ready when ordering parts. Table 11. MDS P-60 Replacement Parts Part Name Description...
  • Page 52: Packaged System Adjustments-Mds P-60

    NEMA 4, weather 98-1926EN resistant Invisible place holder 5.7 Packaged System Adjustments—MDS P-60 Transmit/Receive Audio Level (Analog Interface/Utility Board, P/N 03-2110A01) The Analog Interface/Utility Board has two audio level controls—one to set the transceiver modulation input level from the associated external equipment, and a second level control to set the output audio level fed to the external equipment.
  • Page 53 Order Wire Levels (Analog Interface/Utility Board, P/N 03-2110A01) The MDS P-60 Analog Interface/Utility Board has an Order Wire Level con- trol, R28, used to set the transmit modulation level (deviation) of the audio from the local Order Wire handset’s microphone. The Order Wire handset is plugged into J1 on the Interface/Utility Board.
  • Page 54 (accessible through the hole on the side of its chassis plate). 4. Remove the 1.5 k resistor from J4 and re-install the mating battery con- nector into J4. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 55: Service Drawings And Reference Data

    This section contains assembly drawings and wiring diagrams for the MDS P-60 packaged system. Additionally, schematic diagrams are included for the Analog and Digital Interface/Utility Boards. Invisible place holder Figure 25. MDS P-60 Interior (AC Version) NEMA enclosure not shown MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 56 Invisible place holder. Figure 26. Exploded View of MDS P-60 (AC Version) NEMA enclosure not shown MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 57 Invisible place holder Figure 27. Exploded View of MDS P-60 (DC Version) Analog interface/utility board shown; NEMA enclosure not shown MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 58 NOT USED IN D C P O W E R E D MO D E L S Figure 28. MDS P-60 Packaged System Interconnection Diagram With 03-2110A01 Analog Interface/Utility Board Installed MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 59 Held Failure Handset Audio Audio Terminal J a c k Level Level J a c k Figure 29. Analog Interface/Utility Board, P/N 03-2110A01 Component Locations MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 60 1 2 V B A T T E R Y NOT USED IN D C P O W E R E D MO D E LS Figure 30. MDS P-60 Packaged System Interconnection Diagram with 03-2472Axx Digital Interface/Utility Board Installed MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 61 Invisible place holder Figure 31. Interface Wiring for iNET Transceivers (using COM2 port) MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 62 Invisible place holder Figure 32. Interface Wiring for TransNET Transceivers (or iNET using COM1 port) MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 63 Order Wire Hand- Hand-Held (Alternate Connection) Interface Handset Used Handset Held Terminal/PC Jack* Level* Terminal Connection IN/OUT Figure 33. Digital Interface/Utility Board, P/N 03-2472A03 Component Locations MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 64: Packaged System Adjustments-Mds P-50

    The setting of these controls assumes the associated transceiver has been prop- erly tested and adjusted prior to installation. MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com...
  • Page 65 2. Connect a 1.5 k (1/4 watt or larger) resistor between Pins 2 & 3 of J4. This simulates the load of a discharged battery. MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 66 This section contains assembly drawings and wiring diagrams for the MDS P-50 packaged system. Additionally, schematic diagrams are included for the Analog and Digital Interface/Utility Boards. Invisible place holder Figure 35. MDS P-50 Interior View MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 67 D C P O W E R E D MO D E L S Figure 36. MDS P-50 Packaged System Interconnection Diagram with 03-1105A21 Analog Interface/Utility Board Installed MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 68 Invisible place holder Figure 37. MDS P-50 Analog Interface/Utility Board, P/N 03-1105A21 Component Locations MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 69 NOT US E D IN DC P OW E R E D MODE LS Figure 38. MDS P-50 Packaged System Interconnection Diagram with 03-1467A21 Digital Interface/Utility Board Installed MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Manual RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 70 – PRIMARY POWER INPUT (AC or DC as indicated on CHASSIS chassis label.) GROUND Figure 39. MDS P-50 Digital Interface/Utility Board, P/N 03-1467A21 Component Locations MDS P-60/P-60 HL Reference Manual MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 71 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 72 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 73 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 74 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 75 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 76 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 77 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 78 RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 79 P-60 (AC version) 56, 57 hand-held terminal to packaged system 44 interconnection diagram with analog interface/utility board interconnection with analog interface/utility board (P-50), MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Guide RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 80 (P-50) 67 Mounting dimensions, MDS P-60 13 interconnection diagram with analog interface/utility board Mounting the P-50 enclosure 26 (P-60) 58 Mounting the P-60 enclosure 12 interconnection diagram with digital interface/utility board (P-50) 60, 61, 62 interior view, P-50 66 interior view, P-60 (AC version) 55...
  • Page 81 50 Unpacking and inspection, P-50 26 Unpacking and inspection, P-60 12 Wall mounting instructions, P-50 27 Wall mounting instructions, P-60 13 MDS 05-2818A01, Rev. C MDS P-60/P-60 HL Reference Guide RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 82 MDS P-60/P-60 HL Reference Guide MDS 05-2818A01, Rev. C RSPSupply - 1-888-532-2706 - www.RSPSupply.com http://www.RSPSupply.com/p-8466-MDS-P60-Compact-Enclosure-(One-Radio).aspx...
  • Page 83 IN CASE OF DIFFICULTY... GE MDS products are designed for long life and trouble-free operation. However, this equipment, as with all electronic equipment, may have an occasional component failure. The following information will assist you in the event that servicing becomes necessary.