HIKVISION DS-KD3002-VM Quick Start Manual
HIKVISION DS-KD3002-VM Quick Start Manual

HIKVISION DS-KD3002-VM Quick Start Manual

Video intercom door station.
Hide thumbs Also See for DS-KD3002-VM:

Advertisement

Quick Links

Video Intercom Door Station
Quick Start Guide

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION DS-KD3002-VM

  • Page 1 Video Intercom Door Station Quick Start Guide...
  • Page 2 Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its affiliates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission.
  • Page 3 Video Intercom Door Station·Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 4 Video Intercom Door Station·Quick Start Guide 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
  • Page 5 Video Intercom Door Station·Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Warnings and Cautions: Warnings: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
  • Page 6 Video Intercom Door Station·Quick Start Guide Model Manufacturer Standard DSA-12PFG-12 FUK 120100 Dee Van Electronics Co., Ltd. DSA-12PFG-12 FAU 120100 Dee Van Electronics Co., Ltd. Cautions  Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
  • Page 7: Table Of Contents

    Video Intercom Door Station·Quick Start Guide Table of Contents 1 Appearance ....................1 2 Terminal and Wiring ..................2 2.1 Terminal Description ....................2 2.2 Wiring Description ....................4 2.2.1 Door Lock Wiring ....................4 2.2.2 Door Magnetic Wiring ..................4 2.2.3 Exit Button Wiring .....................
  • Page 8: Appearance

    Video Intercom Door Station·Quick Start Guide 1 Appearance Figure 1-1 Front View Figure 1-2 Rear View Table 1-1 Descriptions of Keys Description Low Illumination Supplement Light Built-in Camera Loudspeaker LCD Display Screen Card Induction Area Keypad Call Button Call Center Key Microphone TAMPER...
  • Page 9: Terminal And Wiring

    Video Intercom Door Station·Quick Start Guide 2 Terminal and Wiring 2.1 Terminal Description Figure 2-1 Terminals and Interfaces Table 2-1 Descriptions of Terminals and Interfaces Name Interface Description USB Interface LAN1 Network Interface LAN2 Analog Interface Power DC 12V DC 12V Power Supply Input Supply Power Supply Output Grounding...
  • Page 10 Video Intercom Door Station·Quick Start Guide Name Interface Description Output) Card Reader Indicator Output (Valid Card Output) TAMP Tamper-proof Input of Wiegand Card Reader AO2- Alarm Relay Output 2 AO2+ ALARM AO1- Alarm Relay Output 1 AO1+ Grounding Serial Port Debugging/Receive data DEBUG Serial Port Debugging/Send data 3.3V...
  • Page 11: Wiring Description

    Video Intercom Door Station·Quick Start Guide 2.2 Wiring Description 2.2.1 Door Lock Wiring Figure 2-2 Door Lock Wiring  Terminal NC1/COM1 is set as default for accessing magnetic lock/electric bolt; terminal NO1/COM1 is set as default for accessing electric strike. ...
  • Page 12: Exit Button Wiring

    Video Intercom Door Station·Quick Start Guide To connect the door magnetic, it is required to set the output of terminal AI2 to be door magnetic with Batch Configuration Tool or iVMS-4200. 2.2.3 Exit Button Wiring Figure 2-4 Exit Button Wiring Terminal S1 is set as default for connecting exit button.
  • Page 13 Video Intercom Door Station·Quick Start Guide OFF in 6.) OFF: Wiegand 34 RS-485 Card Reader Wiring Figure 2-5 RS-485 Card Reader Wiring...
  • Page 14: Alarm Device Input Wiring

    Video Intercom Door Station·Quick Start Guide Wiegand Card Reader Wiring Figure 2-6 External Card Reader Wiring 2.2.5 Alarm Device Input Wiring Figure 2-7 Alarm Device Input Wiring...
  • Page 15: Alarm Device Output Wiring

    Video Intercom Door Station·Quick Start Guide 2.2.6 Alarm Device Output Wiring Figure 2-8 Alarm Device Output Wiring for DS-KD3002-VM...
  • Page 16: Installation

    3.1 Installation Accessory Description Figure 3-1 Front and Side View  The dimension of gang box for model DS-KD3002-VM door station is: 343(length)× 113(width)×55(depth) mm.  The dimensions above are for reference only. The actual size can be slightly different from the theoretical dimension.
  • Page 17 Video Intercom Door Station·Quick Start Guide 1. Chisel a hole in the wall for inserting the gang box. The size of the hole should be larger than that of the gang box. The suggested size of hole is 343.5 (length) × 113.5 (width) ×...
  • Page 18 Video Intercom Door Station·Quick Start Guide Figure 3-3 Install the Door Station 6. Fix the door station to the gang box with 4 crews. Figure 3-4 Tighten the Screws of Device...
  • Page 19: Local Operation

    Video Intercom Door Station·Quick Start Guide 4 Local Operation 4.1 Keys Description Key descriptions of door stations are illustrated in below. Table 4-1 Key Descriptions 1 Description Numeric Key 2 ▲ Numeric Key 4 ▼ Numeric Key 6 ◄ Numeric Key 8 ►...
  • Page 20 Video Intercom Door Station·Quick Start Guide Figure 4-2 Set Password 3. Enter a new password, and confirm the password. The character description for each numeric key is shown in table below. Table 4-2 Character Description Description Description 1,.?!*#- 6mnoMNO 2abcABC 7pqrsPQRS 3defDEF 8tuvTUV...
  • Page 21: Edit Network Parameters

    Video Intercom Door Station·Quick Start Guide 4.3 Edit Network Parameters Purpose: Network connection is mandatory for the use of door station. Steps: 1. Go to the configuration mode. 1) Hold down the * key and the # key for 2s to enter the admin password interface. 2) Enter the admin password, and press the # key.
  • Page 22: Change Password

    Video Intercom Door Station·Quick Start Guide Figure 4-5 Network Parameters Settings Interface 3. Edit network parameters. 1) Move the cursor to parameters to be configured. 2) Press the # key to enter or exit the editing mode. 4. Press the * key to exit the network configuration interface. 4.4 Change Password Purpose: 2 kinds of password are available when using the door station: configuration password...
  • Page 23 Video Intercom Door Station·Quick Start Guide Figure 4-6 Admin Password Interface The default admin password is 888999. 2. Press the numeric keys 4 and 6 to switch to the password settings interface. Figure 4-7 Password Settings Interface Change Configuration Password Steps: 1.
  • Page 24: Call Resident

    Video Intercom Door Station·Quick Start Guide 2. Enter the old password, and the new password, and confirm the new one. 1) Move the cursor to parameters to be configured. 2) Press the # key to enter or exit the editing mode. 3.
  • Page 25: Unlock Door

    Video Intercom Door Station·Quick Start Guide 1. Enter the Community No. and the # key, the Building No. and the # key, the Unit No. and the # key, and the Room No. and the # key. 2. Press the key to start calling the resident.
  • Page 26: Appendix

    Video Intercom Door Station·Quick Start Guide Appendix Installation Notice While installing the indoor station, make sure that the distance between any two devices is far enough to avoid the howling and echo. The distance between two devices is recommended to be longer than 10 meters. Here devices refer to indoor station, outdoor station and master station.
  • Page 27 Video Intercom Door Station·Quick Start Guide UD10774B...

Table of Contents