XM500 TCP/IP MODEM

SPECIFICATIONS

Versions: All include the TCP/IP modem, 2 velcro strips, and
this Product Data Sheet.
XM500-US: US power supply, DB25 to DB9 converter,
RS-232 cable (RJ-45 to DB25), 2 IP address stickers.
XM500-EU: Standard European power supply "EURO-plug",
RS-232 cable (RJ-45 to DB9).
XM500-UK: UK power supply, RS-232 cable (RJ-45 to DB9).
Dimensions: See Fig. 1.
Weight: 4 oz (113g).
TPE:
10BASE-T (Twisted Pair Ethernet).
RJ-45 connector.
IEEE 802.3/Ethernet compliant.
Terminal:
RS-232C serial communications.
RJ-45 connector.
50 to 115,200 bps.
Full modem control.
Hardware and software flow control.
Electrical Ratings:
Voltage: 6 Vdc.
Current: 200 mA.
Power Consumption: 140mA at 5 Vdc.
Environmental Ratings:
Operating temperature: 32 to 122°F (0 to 50°C).
Storage temperature: 14 to 158°F (-10 to +70°C).
Relative humidity: 10 to 95% non-condensing.
Processor and Memory:
Main processor: 68HC000.
Ethernet Coprocessor: SMC91C96.
Memory:
RAM: 64K byte with 2K byte NVRAM.
EPROM: 256K byte.
Software: IP-Connect software is provided to configure the
XM500 modem. The various controllers and workstations
are configured using Honeywell-specific software for serial
communication with EXCEL 5000 and LCBS systems.
Network Management:
SNMP/MIB-II: RFC 1155, 1157, and 1213.
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
74-3468—3
Network Protocols Supported:
ARP: RFC 826.
DHCP: RFC 2131 and 2132.
DNS: RFC 1034 and 1035.
ICMP: RFC 792.
IP: RFC 791.
PPP: RFC 1332, 1661, and 1662.
RARP: RFC 903.
RIP: RFC 1058.
SLIP: RFC 1055.
TCP: RFC 793.
UDP: RFC 768.
Protection Standards: FCC Class A.
Approvals:
CE approval according to the following standards:
EN 55022, Class A
IEC 801-2
IEC 801-3
IEC 801-4
NOTE: The RS-232 and Ethernet cables should be fitted
with non-conductive protective boots (or sleeves)
over the RJ45 connectors to remove electrostatic
discharge susceptibility.
Power-fail and Data Storage
All TCP/IP related initialization data (e.g., IP address, network
mask and gateway) are automatically stored in NVRAM.
All RS-232 related initialization data should be stored in
NVRAM by the user. See the Hayes Command Set
section.
If this is done, the XM500 will resume operation after power-
fail automatically with all preset initializations.
Serial Interfaces: At the front, the XM500 provides two serial
interfaces (see Fig. 2).
Power Supply: At the rear, the XM500 has a socket for the
power supply and an on/off switch. (See Fig. 3.)
LED Lights: Two status indicators for POWER and LINK
integrity (see Fig. 4) with the following meanings:
POWER LED ON: Correct power supply connected.
LINK LED ON: Correct TCP/IP (10bT) connection established.
Link LED equates to dial tone.