Performing repairs may expose voltage sources, moving parts or
compressed air sources, personal injury may occur. Maintenance
other than that recommended in the "Troubleshooting" section of this manual is
not recommended and should be performed by trained service personnel.
PROBLEM
Thermal
Low voltage.
overload
protector cuts
out repeatedly.
Improper ventilation/
temperature too high.
Defective check valve.
Defective valves.
Compressor does not turn
Excessive tank
off when compressor
pressure - safety
reaches "cut-out" pressure.
valve pops off.
Pressure switch "cut-out"
too high.
Air leaks at
Tube fittings are not tight
fittings.
enough.
Air leaks in air
Defective air tank.
tank or at air
tank welds.
8/1/06
10:14 AM
Page 15

TROUBLESHOOTING

CAUSE
Extension cord is wrong length or
gauge. Check extension cord.
Operate compressor in a well
ventilated area.
Contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Set Auto/On/Off switch to the "OFF"
position, if the unit does not shut
off contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Using a soapy water solution check
all exposed fittings for leaks. If
needed reseal fittings with pipe
sealant tape and retighten securely.
Do Not Overtighten. If leaks
continue contact a Trained Service
Technician.
Air tank must be replaced. Do not
repair the leak.
Do not drill into, weld or
otherwise modify air tank or it
will weaken. The tank can rupture
or explode.