Summing In-Line Amplifier, Order Code AA919

3.7 | Tare and UnTare

1.
The Tare function is useful in zeroing the preload on setup.
Click the Tare button to load Zero Value to the amplifier.
Note: Tare limit is 30% of FS. When the preload of load on the
amplifier is more than 30% of FS, Tare command will show an
error.
Figure 3.7a. Tare Option
2.
Click Yes to continue with the Tare function.
Figure 3.7b Tare Validation
3.
The Output Voltage is now set close to zero and the values
are saved to flash memory on the Summing In-Line Ampli-
fier.
4.
Tared output can be reversed by clicking on the UnTare
button.
8 sensing.honeywell.com
Figure 3.7c. UnTare Option
1.
After UnTare, the output will return to original values..
Figure 3.7d. UnTare Results