Summary of Contents for Honeywell X-DA1500EN

  • Page 1 High Efficiency Power Amplifier User Manual TYPE:X-DA1500EN X-DA2250EN X-DA4125EN M_2000060685_EN_1.2...
  • Page 2 Copyright © 2011 Honeywell International Inc. All rights reserved. No part of this document may be reproduced in any form without the written permission of the copyright owner. Disclaimer The contents of this document are subject to revision without notice due to continued progress in methodology, design, and manufacturing.
  • Page 3 This sign means to alert the user that there are non-insulated materials within the enclosure, which pose threats of electrocution if mishandled. This sign means to alert the user of important operation and maintenance instructions. Caution: To avoid electrocution, do not use polarized plug with an extension cord, receptacle, or other outlet unless the blades can be fully inserted to prevent blade exposure.
  • Page 4: Suggestions For Safety

     The product installation and use must comply with local electrical safety regulations.  Honeywell assumes no liability for user errors or misuse that result in a fire or an electrical shock. Transportation Safety  During transportation, do not violently shake the appliance or expose it to corrosive liquids.
  • Page 5  When the power is turned on, do not physically alter the appliance to avoid damaging the equipment.  Honeywell assumes no liability for appliance malfunctions. Please consult qualified technicians for repairs. Manual Labels and Information  Please note the product labels, product categories, power requirements, and other information.
  • Page 6 Declaration of conformity The following standards have been applied to ensure the product conforms with the protection requirements of the council directive 2004/108/EC. Electromagnetic emissions: EN55013:2001+A1:2003+A2:2006 EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2008 Electromagnetic immunity: EN55020:2007 Electrostatic Discharge Immunity EN55020:2007 Electrical Fast Transient / Burst Immunity EN55020:2007 Immunity from Radiated Fields EN55020:2007 Immunity from Conducted Voltages...
  • Page 7 Introduction  The Class-D amplifies audio signal power it receives from audio input devices to maintain clarity and volume when broadcast over many speakers in X-618 PA system. Features  A CLASS-D power amplifier with high efficiency and energy conservation ...
  • Page 8 Front Panel(X-DA1500EN) Front Panel (X-DA2250EN) Front Panel (X-DA4125EN)
  • Page 9 Number Indicator Light Description Power indicator. POWER The light is green when the DA is working normally. Indicates the main power supply status. If this light is turned off, the main power supply is operating normally. AC FAULT If the light turns yellow, the main power supply has experienced a fault.
  • Page 10 Rear Panel(X- DA1500EN) Rear Panel(X- DA2250EN) Rear Panel(X- DA4125EN) Port Description Connects to an external audio input RJ45 Ethernet port device Cooling fan If a DA fault occurs, it is protected, Audio FAULT or it is self-tested, ports A and B input experience a short circuit.
  • Page 11 control Balanced positive input ports Balanced negative input Grounding (Connect to the “-“ port if 1/2/4 the input is an unbalanced input connection.) 100V 100V high impedance audio output Audio 70V high impedance audio output output 1/2/4 ports Common Cooling fan Main power supply power Supplies electricity to the main power port...
  • Page 12: Technical Specifications

    Technical Specifications Parameter Value Nominal output power 1 X 500W 2 X 250W 4 X 125W Main power supply ~ 100V-240V 50/60Hz voltage Backup power supply 21.5V DC ~ 28.5V DC voltage Power consumption <700W Main fuse T10AL 250V Speaker output voltage 100V / 70V 70Hz~18KHz (+1dB ~ -3dB)...
  • Page 13 Parameter Value 4 signal lights 4 Channels 4 peak clipping lights 4 equipment protection lights Number of channels  95%,humidity Operating conditions Operating temperature 0C~+40C Storage temperature -10C~+55C Product dimensions 482 mm×88 mm ×420 mm (width × height × depth) Package dimensions 580 mm×235 mm ×552mm (width ×...
  • Page 14: Package Contents

    Package Contents Number Component Name Quantity High Efficiency Power Amplifier (X-DA1500EN/X-DA2250EN) Network cable (X-DA4125EN) (X-DA1500EN/X-DA2250EN) Input cable terminal (X-DA4125EN) (X-DA1500EN/X-DA2250EN) Output cable terminal (X-DA4125EN) (X-DA2250EN/X-DA4125EN) Safety shield (X-DA2250EN/X-DA4125EN) Screws AC power cable Power connector kit Product manual...
  • Page 15 Life Safety A/V (Guangzhou) Co., Ltd Address: No. 257 Junye Road, Guangzhou GETDD East 510530, China Tel: +86 (0)20 2839 9600 Fax: +86 (0)20 2820 8706 © 2012 Honeywell International Inc. All rights reserved.

This manual is also suitable for: