Panasonic LP-GS Series Serial Communication Command Manual page 109

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

⿎ Data example
Condition:
Object No. = 1, Point No. = 5, Radiation time = 2000, Laser power correction = 100,
X-position = 25.5, Y-position = -7
• Setting
Transmission data
Condition:
When setting 4 points:
Object No. = 1, Point No. = 0, Radiation time = 2000, Laser power correction = 100,
X-position = 25.5, Y-position = 7, X-position = 25.5, Y-position = -7,
X-position = -25.5, Y-position = -7, X-position = -25.5, Y-position = 7
• Setting
Transmission data
⿎ Setting request data : When specifying radiation time and laser power correction ratio for
each point
Start
PRD
code
⿎ Data description
Name
Data length
(> Name in LP-400/V)
Object No.
(> Point radiation No.)
Point No.
Radiation time
Laser power
correction
Total data length
⿎ Data example
Condition:
Object No. = 1, Point No. = 3, Radiation time = 2000, Laser power correction = 100
• Setting
Transmission data
[STX]
PRD
[STX]
PRD
[Object No.] [Point No.]
S
[Radiation time] [Laser power correction]
15-byte
Data content
[byte]
2
"00"–"15": Object No. 1400 to 1415
3
"000"–"049"
7
"00000.1"–"99999.9" [ms]
3
"000"–"999" [%]
15
Fixed-length data.
[STX]
PRD
ME-LP-GS-SR-COMP-3
S
0100502000.0100+025.500-007.000
0100002000.0100+025.500+007.000+025.500
S
-007.000-025.500-007.000-025.500+007.000
(Check
sum)
Specifies the radiation time and laser
power correction ratio by a point.
It is not possible to specify the radiation
time and laser power correction ratio for
the multiple points at once.
The unit of the radiation time is always [ms].
The correction ratio is calculated using the
value set at the laser settings as 100%.
S
0100302000.0100
[CR]
[CR]
[CR]
End code
Remarks
109

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents