Graphic Object Settings (Vec Format File) : Cdc - Panasonic LP-GS Series Serial Communication Command Manual

Laser marker lp-400/v compatible mode
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

3-8-2 Graphic object settings (VEC format file) : CDC

Sets the parameters such as the position and size of the graphic objects (VEC format file).
• This command cannot be used for other than VEC format graphic, such as DXF, BMP, JPEG or HPGL etc.
• The VEC format is a graphic format converted for the laser marker use.
• If the object type set in the specified object number is not the graphic (VEC), the laser marker returns the negative
response.
⿎ Setting request data / response data for readout
Start
CDC
code
Sub command is "S" for the setting request data and "A" for the response data for readout.
⿎ Readout request data
Start
CDC
code
⿎ Data description
Name
(> Name in LP-400/V)
Object No.
(> Logo No.)
System reserved
value
X-scaling
Y-scaling
X-position
Y-position
Rotation angle
Laser power
correction
Scan speed
correction
Pulse cycle
correction *
Total data length
* Only for LP-RF series and LP-RV series.
106
[Object No.] [System reserved value]
[X-scaling] [Y-scaling] [X-position] [Y-position]
[Rotation angle] [Laser power correction]
Sub
command
[Object No.]
R
2-byte
Data length
[byte]
2
"00"–"15": Object No. 1200 to 1215
1
"0"–"9", "A"–"F"
8
"0010.000"–"1000.000" [%]
8
8
"-999.999"–"+999.999" [mm]
8
7
"-180.00"–"+180.00" [°]
3
"000"–"999" [%]
3
"001"–"999" [%]
(3)
"001"–"999" [%]
48
The data length is fixed.
or
• LP-GS/LP-RC series: 48-byte
51
• LP-RF/LP-RV series: 51-byte
[Scan speed correction]
[Pulse cycle correction]
LP-GS/LP-RC: 48-byte
LP-RF/LP-RV: 51-byte
(Check
End code
sum)
Data contents
ME-LP-GS-SR-COMP-3
(Check
sum)
Remarks
This value does not affect the settings
anymore.
The correction ratio is calculated using
the size of the saved graphic data as
100%.
Specifies the origin coordinate of the
graphic.
The graphic origin is the position
specified when converting the graphic
data into a VEC file.
The rotation center is the origin of the
graphic.
The correction ratio is calculated using
the value set at the laser settings as
100%.
End code

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents