Turning Off The Appliance - Honeywell VR8215 Series Installation Instructions Manual

Direct ignition combination gas controls
Table of Contents

Advertisement

VR8215S,T DIRECT IGNITION COMBINATION GAS CONTROLS
To Turn ON Appliance
STOP! Read the Warnings
Above Before Proceeding.
1. The lighting sequence on this appliance is
automatic; do not attempt to manually light the
main burner.
2. If the furnace does not come on when the
thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.
3. Remove the burner access panel if provided on
your appliance.
4. Push the on-off switch to the OFF
position.
5. Wait five minutes to allow any gas in the
combustion chamber to vent. Then if you smell
gas, STOP! Follow Step 1 in the Warning above. If
you do not smell gas, continue with the next step.
6. If you do not smell gas, push the electronic on-off
switch to the ON position.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
customer.honeywell.com
® U.S. Registered Trademark
© 2008 Honeywell International Inc.
69-2253—01
M.S. 08-08
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the appliance does not turn on, turn the gas
control switch to OFF and contact a qualified
service technician for assistance.

Turning Off the Appliance

Vacation Shutdown
Set the thermostat to the desired room temperature while
you are away.
Complete Shutdown
1. Turn off power to the appliance.
2. Turn off the gas supply to the appliance.
3. Push the on-off switch to the OFF
position. Appliance will completely shut off.
4. Follow the procedure in the Instructions to the
Homeowner section above to resume normal
operation.