Honeywell CentraLine CLIOL822A Product Data page 2

Lonworks bus i/o modules
Table of Contents

Advertisement

LONWORKS BUS I/O MODULES – PRODUCT DATA
OVERVIEW
ANALOG INPUT
LonWorks
BUS MODULES
CLIOL821A
CONTROLLER
order number
LonWorks Bus I/O Modules
CLIOL821A
L
W
ON
ORKS
CLIOL822A
L
W
ON
ORKS
L
W
CLIOLR822A
ON
ORKS
CLIOL823A
L
W
ON
ORKS
L
W
CLIOL824A
ON
ORKS
CLIOLR824A
L
W
ON
ORKS
Terminal Sockets
XS821-22
Push-in terminal socket for AI/AO modules (incl. bridge connector, swivel label)
XSU821-22
Screw-type terminal socket for AI/AO modules (incl. bridge connector, swivel label)
XS823
Push-in terminal socket for BI modules (incl. bridge connector, swivel label)
Screw-type terminal socket for BI modules (incl. bridge connector, swivel label)
XSU823
XS824-25
Push-in terminal socket for relay/floating output modules (incl. bridge connector, cross connector, swivel label)
Screw-type terminal socket for relay/floating output modules (incl. bridge connector, cross connector, swivel label)
XSU824-25
order number
XS814
Ten Auxiliary Terminal Blocks (for distribution of signals/power). Each terminal block includes two
groups with seven internally-connected push-in terminals.
20 Cross-Connectors for connection of six relay commons. One Cross-Connector is included in the
XS815
Terminal Socket package.
XS816
10 Bridge Connectors. One Bridge Connector is included in the Terminal Socket package.
XAL10
10 Swivel Labels Holders (for attaching the application-specific label printed with CARE / COACH AX /
COACH NX). One Swivel Label Holder is included in each Terminal Socket package. NOTE: Phased
out.
NOTE: The inputs and outputs of all CentraLine analog and binary I/O modules are protected against short circuit,
24 VAC +20%, and 40 VDC.
In the case of the relay outputs of other CentraLine I/O modules (i.e., relay output modules, floating output
modules, and mixed I/O modules), appropriate fusing must be provided to ensure that permissible load currents
are not exceeded. See also sub-section "Features" in section "Relay Output Modules" on pg. 14.
EN0Z-0980GE51 R0119
pluggable
pluggable
ANALOG OUTPUT
CLIOLR822A
CLIOL822A
XS821-22
XSU821-22
Fig. 1. Overview of CentraLine LonWorks Bus I/O Modules
Table 1. Overview of CentraLine LonWorks Bus I/O Modules
Bus Bus Analog Input Module (with 8 analog inputs)
Bus Bus Analog Output Module (with 8 analog outputs)
Bus Bus Analog Output Module (with 8 analog outputs and manual overrides)
Bus Bus Binary Input Module (with 12 binary inputs)
Bus Bus Relay Output Module (with 6 relay outputs)
Bus Bus Relay Output Module (with 6 relay outputs and manual overrides)
Table 2. Overview of auxiliary parts and spare parts
pluggable
pluggable
BINARY INPUT
RELAY OUTPUT
CLIOLR824A
CLIOL823A
CLIOL824A
XS823
XS824-25
XSU823
XSU824-25
description
description
2
LonWorks Bus

Hide quick links:

Advertisement

Table of Contents