Service Mode; Setting The Test Mode; Emergence Memory Address; C Page Emergence Memory Address - Sony HANDYCAM DCR-TRV130E Service Manual

Digital video camera recorder
Hide thumbs Also See for HANDYCAM DCR-TRV130E:
Table of Contents

Advertisement

4-3.

SERVICE MODE

Additional note on adjustment
Note: After the completion of the all adjustments, cancel the service mode
by either of the following ways.
1) After data on page: D is restored, unplug the main power supply
and remove the coin lithium battery. ( In this case, date and time
and menu setting have been set by users are canceled. Perform
resetting.)
2) After data on page: D is restored, select page: 0, address: 01, and
return the data to 00. And when data on page:2 and 3 are changed,
return data to the original condition.

1. Setting the Test Mode

Page D
Address 10
Data
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off (8.4Vdc).
• After completing adjustments/repairs, be sure to return the data
of page: D address: 10 to 00, and press the PAUSE button of the
adjustment remote commander. And select page: 0, address: 01,
and set data: 00.
Function

2. Emergence Memory Address

2-1. C Page Emergence Memory Address

Page C
Address
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data "00" is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(F4 to F7). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note : After completing adjustments, be sure to initialize the data of
addresses F4 to FF to "00".
Initializing method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 37, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
5-52
Address F4 to FF
Contents

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv130Handycam dcr-trv130

Table of Contents