Technical Specifications - Buffalo CP240 Instruction Manual

6 burner bbq griddle/grill combination
Table of Contents

Advertisement

UK
Fault
Flare-up
Grease buildup
Excessive fat in meat
Excessive cooking
temperature
Unable to fill LP
Some dealers have older fill
bottle
nozzles with worn threads
One burner does
Grease buildup or food
not light from other
particles at end of carryover
burner(s)
tube

Technical specifications

Country of Destination
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, LU, LV,
PT, SK, SI
BE, CY, DK, EE, FI, HU, LT,
NL, NO, SE, SI, SK, RO,
HR, TR, BG, LU, MT
AT, CH, DE, SK
PL
Specifications subject to change without prior notice.
Compliance
The product must not be disposed of as household waste. To help prevent possible harm to human
health and/or the environment, the product must be disposed of in an approved and environmentally safe
recycling process. For further information on how to dispose of this product correctly, contact the product
supplier, or the local authority responsible for waste disposal in your area.
BUFFALO parts have undergone strict product testing in order to comply with
regulatory standards and specifications set by international, independent, and
federal authorities.
BUFFALO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any
means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO
reserve the right to change specifications without notice.
12
CP240_UK_A5_v2_170717.indb 12
Probable Cause
Clean burners and inside of grill/ firebox
Trim fat from meat before grilling
Set the control knob to a lower setting
Turn worn nozzles don't have enough "bite" to
engage the valve. Try a second LP gas dealer.
Clean carry-over tube with wire brush
Model: CP240
Appliance Category
Gas and Supply Pressure
Butane (G30) 28-30 mbar
X
I3+(28-30/37)
Propane (G31) 37 mbar
I3B/P(30)
Butane/Propane 30 mbar
I3B/P(50)
Butane/Propane 50 mbar
I3B/P(37)
Butane/Propane 37 mbar
of BUFFALO.
Telephone Helpline: 0845 146 2887
Solution
Burners (x6)
Injector Size Ø
0.93mm
0.93mm
0.93mm
0.82mm
0.86mm
845
2017/7/17 10:40

Advertisement

Table of Contents
loading

Table of Contents