Download Print this page
Honeywell Limitless WGLA Series Quick Start Manual
Honeywell Limitless WGLA Series Quick Start Manual

Honeywell Limitless WGLA Series Quick Start Manual

Limit switch. used in conjunction with the limitless wpmm series
Hide thumbs Also See for Limitless WGLA Series:

Advertisement

Quick Links

Quick Start Guide for the
Limitless™ Series WGLA Limit Switch
used in conjunction with the Limitless™ WPMM Series
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
Honeywell does not recommend using devices for critical
control applications where there is, or may be, a single point
of failure or where single points of failure may result in an
unsafe condition. It is up to the end-user to weigh the risks
and benefits to determine if the products are appropriate for
the application based on security, safety and performance.
Additionally, it is up to the end-user to ensure that the control
strategy results in a safe operating condition if any crucial
segment of the control solution fails.
Honeywell customers assume full responsibility for learning
and meeting the required Declaration of Conformity,
Regulations, Guidelines, etc. for each country in their
distribution market.
Failure to comply with these instructions could result in
death or serious injury.
Sensing and Control
WARNING
RF EXPOSURE
To satisfy FCC RF exposure requirements for mobile
transmitting devices, a separation distance of 20 cm or
more should be maintained between the antenna of this
device and persons during device operation To ensure
compliance, operation at closer than this distance is not
recommended. The antenna used for this transmission
must not be co-located in conjunction with any other
antenna or transmitter.
Failure to comply with these instructions could result
in death or serious injury.
WARNING
The WGLA must be installed in accordance with the
requirements specified in this document. See Section 3
and Section 4 for EIRP requirements. Only the
specified EIRP power settings, antenna types and
gains and cable lengths (attenuation) as outlined in this
document are valid for WGLA Series installations.
CAUTION
Power to the WGLA should not be applied (ensure
battery is removed) during installation of antenna as
damage could occur to the WGLA electronics.
ISSUE 1
50053338

Advertisement

loading

Summary of Contents for Honeywell Limitless WGLA Series

  • Page 1 WARNING must not be co-located in conjunction with any other antenna or transmitter. Honeywell does not recommend using devices for critical Failure to comply with these instructions could result control applications where there is, or may be, a single point in death or serious injury.
  • Page 2: Antenna Connection

    RISK OF DEATH OR SERIOUS INJURY FROM EXPLOSION OR FIRE If WGLA is to be returned to Honeywell for any reason, the battery MUST be removed prior to shipping. Dispose of used batteries promptly per local regulations or the battery manufacturer’s recommendations.
  • Page 3: Pairing Mode

    The operation and LED functions for the WPMM are visually depicted and described in Section 5.4 of the WGLA Installation and Technical manual. This file is also located as a separate file on this CD or at www.honeywell.com/sensing. Honeywell Sensing and Control...
  • Page 4 Record the WGLA Sequence # on identification labels and apply to the WGLA housing in desired locations (See Figure 6). Repeat Steps 2-7 to add additional WGLA switches. Up to 16 WGLAs can be paired to a single WPMM. Honeywell Sensing and Control...
  • Page 5 NOTE: Use a blunt object, such as a paper clip or tooth pick to actuate the function switch NOTE: Use a blunt object, such as a paper clip or tooth pick to actuate the function switch Figure 6. Limitless™ Switch Label Placement Honeywell Sensing and Control...
  • Page 6 (See installation drawing at www.honeywell.com/sensing) Figure 7. Limitless™ WGLA mounting hole diagram The WGLA Series switch has many actuator types and associated specifications. Additional information can be found at: www.honeywell.com/sensing Honeywell Sensing and Control...
  • Page 7: Antenna Adjustment

    To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this transmitter must not be co-located in conjunction with any other antenna or transmitter. Failure to comply with these instructions could result in death or serious injury. Honeywell Sensing and Control...
  • Page 8 +1-305-805-8188 +1-305-883-8257 Fax While we provide application assistance personally, through USA/Canada +1-800-537-6945 our literature and the Honeywell web site, it is up to the +1-815-235-6847 customer to determine the suitability of the product in the +1-815-235-6545 Fax application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
  • Page 9 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell WGLA1A01BA1A WGLA1A02BA1A WGLA1A02BA1B WGLA1A02BA4J WGLA1A04BA1A WGLA1A04BA1B WGLA1A04BA4J WGLA1A04BB WGLA1A04BC WGLA1A02AA1A WGLA1A02AA1B WGLA1A02AA4J WGLA1A04AA1A WGLA1A04AA1B WGLA1A04AA4J WGLA1A02BB WGLA1A02BC WGLA1A02BD...