6. Select SAVE again to complete enrollment.
NOTE: If steps 5 and 6 are not completed, the device
will automatically be deleted from the system when
exiting Programming mode.
After enrolling, verify adequate signal strength by
conducting Go/No Go tests (see controller's instructions)
with the device in its intended mounting location. Adjust
the device location and orientation as necessary.
24-Hour Enrollment Deletion and Default
If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from
the unintended panel, reset the device to factory
default setting:
1. Open the cover and remove the battery.
2. Hold down the tamper switch while reinserting the
battery.
3. Reattach the cover.
This procedure is available for 24 hours after
enrollment with a panel and the device remains
powered (battery installed).

LED Indications

LED
about 20 seconds, then
(while in Programming Mode)

Battery Replacement

• Push the bottom latch of the
mounting bracket back to disengage
it. Then slide the back housing up
and out to remove it from the
mounting bracket.
• Slide the front and back housings in
opposite directions and pull the
housings apart.
• Remove the battery, wait 10
seconds, then insert a new battery.
Recommended batteries:
Duracell DL123A
Honeywell 466
Huiderui CR123A
Panasonic CR123A
• Place the front and back housings
together and slide them together.
BATTERY CAUTION: Risk of fire, explosion
and burns. Do not recharge, disassemble, heat
above 212°F (100°C) or incinerate. Dispose of
used batteries properly. Keep away from
children.
NOTE: Constant exposure to high or low
temperature or high humidity may reduce
battery life.
Rapid Flashes for
ON for 3 seconds
Slow Flashes
ON
For the Lyric™ Gateway
Enroll and program using AlarmNet 360™.
Using AlarmNet 360
When AlarmNet 360 is ready to enroll, remove the sensor
battery tab or use the magnet if the tab is removed. After
the device is enrolled, the Green LED is on for 3 seconds.
Status
Power Up – Enrollment
Power Up – Device enrolled; Wall or Cover Tamper activated. To stop
flashes, clear the tamper condition by reconnecting to the mounting plate
and reattaching the cover. It also times out after 10 minutes.
Sensor LED toggles on and off when the sensor is selected. See Sensor
Location Feature. (Not available with Lyric Gateway.)