Wired zone expander/relay module

Advertisement

8 7
6 5
4 3
NOTE: ADDRESSES 16-31 MAY NOT BE AVAILABLE; CONSULT THE HOST CONTROL PANEL INSTALLATION INSTRUCTIONS.
ADDRESS "0" SETTING SHOWN.
EOLR value is 2K ohms.
U L
For UL, use 14-22AWG wire, and no more than one wire may be connected per terminal. Use UL Listed EOL
resistors.
{
RELAYS
"OFF"
IF EOLR OPTION SELECTED, TERMINATE EACH PROGRAMMED
ZONE WITH 2K OHM END-OF-LINE RESISTOR (EACH ZONE'S MAX.
LOOP RESISTANCE: 300 OHMS + EOL). IF NORMALLY CLOSED
OPTION SELECTED, CONNECT ALL ZONES AS NC LOOPS.
SEE DETAIL A
FOR LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE INSTALLATION AND SETUP GUIDE FOR
THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED.
Federal Communications Commission (FCC) Part 15
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes
or modifications could void the user's authority to operate the equipment.
FCC CLASS B STATEMENT:
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions,
may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance
with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
FCC/IC STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
This device complies with Part 15 of the FCC rules and RSS 210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1)
Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception
indésirable.
ÊN8910V3VŠ
N8910V3 3/14 Rev. B
DIP SWITCH: (WHITE AREAS DENOTE SWITCH HANDLES)
2 1
POSITION 1:
DETERMINES ZONE A's RESPONSE TIME:
ON = NORMAL (300MS)
OFF = FAST (10MS) RESPONSE TO AN OPEN 300MS ZONE A SETTING SHOWN (AS SHIPPED).
POSITIONS 2-6:
DETERMINE ZONE EXPANDER'S ADDRESS. CONSULT CONTROL'S INSTRUCTIONS
FOR ADDRESS USE. SWITCH SETTING SHOWN SET FOR ADDRESS "0".
SW #
0
1
2
3
4
5
6
2
ON — ON — ON — ON — ON — ON — ON — ON —
3
ON ON — — ON ON — — ON ON — — ON ON — —
4
ON ON ON ON — — — — ON ON ON ON — — — —
5
ON ON ON ON ON ON ON ON — — — — — — — —
ON ON ON ON ON ON ON ON
6
DIP SWITCH POSITION #7: SELECTS USE OF NC OR EOLR ZONES.
POSITION 7:
ON = ALL ZONES NORMALLY CLOSED
POSITION 8:
OFF = ALL ZONES EOLR SUPERVISED UL: SET TO OFF (EOLR)
DIP SWITCH POSITION #8: CASE TAMPER ON = DISABLED OFF = ENABLED
{
NO
WHT
RLY
GRY
NC
2
C
VIO
GND
BLK
{
NO
YEL
1
RLY
NC
ORG
1
BRN
RELAY
C
CONNECTOR
1
2
3
TB1
REED
(TAMPER)
ZONES A
B
SWITCH
DETAIL A
For the latest warranty information, please go to:
http://www.security.honeywell.com/hsc/resources/wa
("—" means "OFF")
4 2 2 9 A D D R E S S S E T T I N G S
7
8
9 10 11 12 13 14 15
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
ON — ON — ON — ON — ON — ON — ON — ON —
ON ON — — ON ON — — ON ON — — ON ON — —
ON ON ON ON — — — — ON ON ON ON — — — —
ON ON ON ON ON ON ON ON — — — — — — — —
— — — — — — — —
ON ON ON ON ON ON ON ON
8 7 6 5 4 3
2 1
DIP SWITCH
RELAY
OR BOTH
2
4229
RELAY
WIRED ZONE
1
EXPANDER/RELAY
MODULE
TB1
1
2
4
5
6
7
8
3
A
B
C
D
E
F
— — — — — — — —
4-PIN CONSOLE
PLUG
1
2
3
4
EITHER
DATA OUT
GRN
CAN BE
4
TO CONTROL
USED
BLK
(–) GROUND
3
RED (+) 12VDC
2
YEL
DATA IN FROM
1
CONTROL
9
10
11
12
TB2
G
H
ZONES
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2008 Honeywell International Inc.