Honeywell SMV800 Quick Start Installation Manual page 10

Smartline multivariable transmitter
Hide thumbs Also See for SMV800:
Table of Contents

Advertisement

Flameproof:
Sira 15ATEX2039X
II 1/2 G Ex db IIC T6..T5
Ga/Gb
II 2 D Ex tb IIIC T
o
o
95
C..T125
C Db
Intrinsically Safe:
Sira 15ATEX2039X
II 1 G Ex ia IIC T4 Ga
ATEX
Non Sparking and
Intrinsically Safe:
Sira12ATEX4234X
II 3 G Ex ec IIC T4 Gc
Standards: EN 60079-0: 2012+A11: 2013; EN 60079-1 : 2007; EN
60079-11 : 2012; EN 60079-31 : 2014
60529 : 2000 + A1; EN 60079-15 : 2010
Enclosure: IP66/ IP67
Intrinsically Safe:
IECEx SIR 15.0022X
Ex ia IIC T4 Ga
Non Sparking:
IECEx SIR 15.0022X
Ex ec IIC T4 Gc
Flameproof:
Ex db IIC T6..T5 Ga/Gb
IECEx
o
o
Ex tb IIIC T 95
C..125
C Db
Enclosure: IP66/ IP67
Standards: IEC 60079-0: 2011; IEC 60079-1 : 2007; IEC 60079-11:
2011; IEC 60079-15 : 2011; IEC 60079-31: 2013; IEC 60079-26: 2006
Intrinsically Safe:
Ex ia IIC T4 Ga
CCoE
Non Sparking:
(India)
Ex ec IIC Gc
Flameproof:
Ex db IIC T6..T5 Ga/Gb
o
o
Ex tb IIIC T95
C..T125
C Db
Intrinsically Safe:
Ex ia IIC T4 Ga
SAEx
Non Sparking:
(South
Ex ec IIC Gc
Africa)
Flameproof:
Ex db IIC T6..T5 Ga/Gb
o
o
Ex tb IIIC T95
C..T125
C Db
Enclosure: IP66/ IP67
MODBUS Communications
AGENCY
TYPE OF PROTECTION
Explosion proof:
Class I, Division 1, Groups A, B, C, D
Dust Ignition Proof:
Class II, III, Division 1, Groups E, F, G
Suitable for Division 1, Class III;
Zone 0/1, Ex db IIC T6..T5 Ga/Gb
Class I, Zone 0/1, AEx db IIC T6..T5
Ga/Gb
o
Ex tb IIIC T 95
C Db
Class II, Zone 21, AEx tb IIIC T 95
Db
Non-Incendive and Intrinsically
Safe:
CSA-
Class I, Division 2, Groups A, B, C, D
Canada
Ex nA IIC T4 Gc
Class I Zone 2 AEx nA IIC T4 Gc
Enclosure: Type 4X/ IP66/ IP67
Standards: CSA C22.2 No 0: 2010; CSA C22.2 No. 0-M91; CSA
C22.2 No 25: 1966; CSA C22.2 No 30M; 1986; CSA C22.2 No.
142M: 1987; CAN/ CSA-C22.2 No.157: 1992; CSA C22.2 No 213M:
1987; CSA C22.2 No 60529: 2005; CSA C22.2 No 60079-0: 2011;
CSA C22.2 No 60079-1: 2011; CSA C22.2 60079-11: 2011; CSA
C22.2 60079-15: 2012; CSA C22.2 60079-31: 2012; ISA 12.12.01:
2010; ANSI/ ISA 60079-0: 2009; ANSI/ ISA 60079-1: 2012; ANSI/
ISA 60079-11: 2011; ANSI/ ISA 60079-15: 2009; ANSI/ ISA 60079-
26 : 2011; ANSI/ ISA 60079-31 : 2012; ISA 60079-27: R2011; UL
913: ed 6; UL 916: 1998
A4. Marking ATEX Directive
General:
The following information is provided as part of the labeling of the transmitter:
• Name and Address of the manufacturer
• Notified Body identification: DEKRA Quality B.V., Arnhem, the Netherlands
o
T5/ T95
C: -50 ºC to
Note 1
85ºC
T6: -50 ºC to 65ºC
Note 2
o
o
T4: -50
C to 70
C
o
o
Note 1
T4: -50
C to 85
C
EN 60079-26 : 2007; EN
o
o
Note 2
T4: -50
C to 70
C
o
o
Note 1
T4: -50
C to 85
C
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
o
o
T4: -50
C to 70
C
Note 2
o
o
Note 1
T4: -50
C to 85
C
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
o
o
Note 2
T4: -50
C to 70
C
o
o
Note 1
T4: -50
C to 85
C
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
Ambient Temperature
o
o
T5: -50
C to 85
C
o
o
T6: -50
C to 65
C
o
C
o
o
T4: -50
C to 85
C
Intrinsically Safe:
Ex ia IIC Ga
Non Sparking:
Ex ec IIC T4 Gc
Flameproof:
Ex db IIC T6..T5 Ga/Gb
o
o
Ex tb IIIC T 95
C..T125
C
INMETRO
Db
(Brazil)
Enclosure: IP66/ IP67
Standards: ABNT NBR IEC 60079-0:2013 (IEC 60079-0:2011); ABNT NBR IEC 60079
11:2013 (IEC 60079-11:2011); ABNT NBR IEC 60079-15:2012 (IEC 60079-15:2010); A
ABNT NBR IEC 60079-31:2014 (IEC 60079-31:2013).
Intrinsically Safe:
Ex ia IIC T4 Ga
Non Sparking:
Ex nA IIC T4 Gc
NEPSI
Flameproof:
(CHINA)
Ex d IIC T6..T5 Ga/Gb
o
Ex tb IIIC Db T95
C..T125
Db
Enclosure: IP66/ IP67
Flameproof:
Ex d IIC T6..T5
KOSHA
o
o
Ex tD A21 T 95
C..T125
(Korea)
Intrinsically Safe:
Ex ia IIC Ga
Ex d IIC T6..T5 Ga/Gb
o
Ex tb IIIC T95
C Db
Intrinsically Safe:
Ex ia IIC T4 Ga
EAC Ex
Non Sparking:
2 Ex nA IIC T4 Gc
Enclosure : IP 66/67
Notes
1. Operating Parameters:
Current= 4-20 mA Normal (3.8 – 23 mA Faults)
Voltage= 11 to 42 V
2. Intrinsically Safe Entity Parameters
Vmax= Ui= 30 V
Imax= Ii= 225mA
A.5 Conditions of Use" for Ex Equipment", Hazardous Location
Equipment or "Schedule of Limitations":
Apparatus Marked with Multiple Types of Protection
The user must determine the type of protection required for installation the equipment.
The user shall then check the box [] adjacent to the type of protection used on the
equipment certification nameplate. Once a type of protection has been checked on the
nameplate, the equipment shall not then be reinstalled using any of the other
certification types.
Painted surface of the SMV800 may store electrostatic charge and become a source of
ignition in applications with a low relative humidity less than approximately30% relative
humidity where the painted surface is relatively free of surface contamination such as
dirt, dust or oil. Cleaning of the painted surface should only be done with a damp cloth.
Flame-proof Installations: The Transmitter can installed in the boundary wall
between an area of EPL Ga/ Class I Zone 0/ Category 1 and the less hazardous area,
EPL Gb/ Class I Zone 1/ Category 2. In this configuration, the process connection is
installed in EPL Ga/ Class I Zone 0/ Category 1, while the transmitter housing is
located in EPL Gb/ Class I Zone 1/ Category 2.
Consult the manufacturer for dimensional information on the flameproof joints for
repair.
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE
PRESENT
Non-Incendive Equipment:
Division 2: This equipment is suitable for use in a Class I, Division 2, Groups A, B, C,
D; T4 or Non-Hazardous Locations Only
WARNING: DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE
PRESENT
Intrinsically Safe: Must be installed per drawing 50128060
The enclosure is manufactured from low copper aluminum alloy. In rare cases, ignition
sources due to impact and friction sparks could occur. This shall be considered during
Installation, particularly if equipment is installed a Zone 0 location.
If a charge-generating mechanism is present, the exposed metallic part on the
enclosure is capable of storing a level of electrostatic that could become Incendive for
IIC gases. Therefore, the user/ installer shall implement precautions to prevent the
buildup of electrostatic charge, e.g. earthing the metallic part. This is particularly
important if equipment is installed a Zone 0 location.
WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR
USE IN HAZARDOUS LOCATIONS
All Protective Measures:
WARNING: FOR CONNECTION IN AMBIENTS ABOVE 60
o
o
Note 2
T4: -50
C to 70
C
o
o
Note 1
T4: -50
C to 85
C
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
o
o
Note 2
T4: -50
C to 70
C
o
o
Note 1
T4: -50
C to 85
C
T5: -50 ºC to 85ºC
Note 1
o
C
T6: -50 ºC to 65ºC
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
C
o
o
Note 2
T4: -50
C to 70
C
T5: -50 ºC to 85ºC
Note 1
T6: -50 ºC to 65ºC
Note 2
T4: -50 ºC to 70ºC
o
o
Note 1
T4: -50
C to 85
C
Ci=4 nF
Li= 0 uH
o
o
C USE WIRE RATED 105
C
Pi= 0.9 W

Advertisement

Table of Contents
loading