1 Overview
The Honeywell HPT724 is a programmable LCD timer that is designed to support a wide range of applications. Such
applications can include: home and building automation, security, access control, lighting control, etc. The HPT724 is
equipped with an independently controlled form "C" relay contact that provides many latching and/or momentary
operations during a program schedule of your choice. The EE prom memory allows for programming 24 hour 365 day
events prior to/during field installation. Events may be set for single or multiple operations on a daily and/or weekly
schedule. The block programming feature enables repeating and event on any combination of consecutive days. The
HPT724 will compensate for daylight saving time if desired. Individually selected holiday exceptions can be
programmed to over-ride regularly scheduled events.

2 Specifications

12/24 volts, 500mA AC or DC operation.
Standby Current: 10 mA (relay off), 50 mA (relay on).
Battery Charging Current: 100 mA.
Form "C" relay contacts are rated 10 amp @ 120 VAC/28 VDC.
EE Prom memory protects against loss of programming due to power failure.
Accurate crystal-controlled clock (displays time in military format).
Momentary and/or latching events.
50 individually programmed daily/weekly events.
Block programming capacity can accommodate a total of 350 events per week.
10 programmable holiday dates.
"First man in" option.
Alphanumeric LCD display simplifies programming.
Standard or daylight saving settings.
Automatic compensation for leap year.
Built-in charger for 12 VDC sealed lead acid or gel type batteries (standby battery maintains operation during power
failure until discharged).
Lithium battery backup maintains clock (optional; battery is 3V, model CR2032).
Board Dimension: 5.25"W x 3"L x 1"D (approximate).

3 Installation Instructions

1.
Mount HPT724 in desired location, using suitable standoffs/fasteners, tape or HST34 snap track.
2.
Connect 12 or 24 volts at 500 mA of AC or DC to terminals marked [+DC-- ~AC~]. (When using DC, carefully
observe polarity.)
3.
Connect 12 VDC battery (optional) to terminals marked [+BAT-- 12VDC].
4.
Insert lithium battery (optional/not included) in battery holder with the positive (+) side facing up (Fig-1).
5.
Connect devices to be controlled to the dry outputs marked [NO, C, NC].
6.
Program clock and desired event schedule (see Sec-5).
Programmable LCD Timer
PN 52765:A
1/25/06
Product Installation Document
Continued on next page...
HPT724
ECN 05-637

Advertisement

loading

Summary of Contents for Honeywell HPT724

  • Page 1: Specifications

    Product Installation Document 1 Overview The Honeywell HPT724 is a programmable LCD timer that is designed to support a wide range of applications. Such applications can include: home and building automation, security, access control, lighting control, etc. The HPT724 is equipped with an independently controlled form “C”...
  • Page 2: Basic Operation

    4 Basic Operation The HPT724 controls an independently operated dry form “C” relay output. Relay can be programmed to: turn on (latch), turn off (release latch), or pulse (momentary toggle) at a specified time and day (this is referred to as an event).
  • Page 3: Programming Instructions

    ENTER to accept. Next, select either DS (daylight savings mode) or ST (standard time mode) by sepressing SET until “ENTER to SET BK: appears in display as shown below. ENTER to SET BK Continued on next page... HPT724 Installation Document P/N 52765:A 1/25/06...
  • Page 4 Next, select HL to indicate as holiday event and time by using UP and DWN push buttons and depress ENTER to accept. You may continue to program more holiday events by repeating the previous steps or exit programming by depressing SET. Continued on next page... HPT724 Installation Document P/N 52765:A 1/25/06...
  • Page 5 Depressing UP push button will now clear all events previously programmed. If you wish to escape from this selection, depress any of the other push buttons; SET, ENTER, or DWN. For additional information: • Visit our website at http://www.honeywellpower.com • Contact Technical Support at 1(877) HPP-POWR • E-mail us at hpp.techserv@honeywell.com HPT724 Installation Document P/N 52765:A 1/25/06...
  • Page 6 Customer Event Log Event # Relay # Day/Block Holiday Dates Event Type HPT724 Installation Document P/N 52765:A 1/25/06...